Calibration of Neuromusculoskeletal Models Using Differentiable Physics: Recommendations for Improving Model Accuracy

Philip Sanderink, Yingfan Zhou, Shuzhen Luo, Cheng Fang
In 30 seconds

This preprint compares four calibration modules for a differentiable model of the human arm. On movements held out from calibration, learning bone dynamics cut average torque loss by 10.9%, while estimating deep muscle activity with muscle synergies cut it by 9.6% when calibration weights were carried over. Both changes improved the agreement between torque estimates used in personalized biomechanical models.

Research question

Which calibration modules, alone or in combination, reduce torque loss on movements excluded from calibration?

Problem

Personalizing a model of the arm requires estimating how much joint torque the muscles produce. Surface electromyography (EMG) misses deep muscle activity, and the torque calculated from measured motion depends on bone properties typically estimated from a generic template. Errors on either side can distort the calibration.

Previous approach

Simulated annealing and particle swarm optimization can take hours on nonlinear muscle models. Earlier differentiable studies assessed muscle synergy extrapolation and bone parameter fitting separately, and the earlier bone fitting results came from simulation.

New approach

The team rebuilt the OpenSim MoBL ARMS Dynamic Upper Limb model in PyTorch with a 3-DoF shoulder, a 2-DoF elbow, 11 superficial muscles and 5 deep muscles. Automatic differentiation and Adam fitted the model by minimizing the root-mean-square gap between EMG-driven forward dynamics and motion-based inverse dynamics torques. Four optional modules estimated deep muscle EMG from Non-negative Matrix Factorization synergies, fitted bone mass, center of mass and inertia, adjusted the geometry of objects that guide muscle paths, or added joint constraint torques to the loss. The team recorded surface EMG with Delsys Trigno at 1 kHz and motion with OptiTrack at 100 Hz. Each fit optimized 40 to 115 parameters for 300 epochs at a learning rate of 0.05 on an AMD Ryzen 7 PRO 7840U CPU.

Results

The team compared 16 calibration configurations on human recordings from four healthy men. The highest-quality trial was retained for each movement, from three trials per calibration movement across four movements and two trials per test movement across nine movements. Table I's best setup, R-SYN_ID_CB_CG, refitted synergies and weights on the test movements. Against MAP_ID_SB_SG, mean torque loss ± SD fell from 3.11 ± 0.65 to 1.77 ± 0.54 Nm for elbow flexion, from 3.96 ± 0.81 to 2.83 ± 0.88 Nm for shoulder elevation, and from 4.27 ± 0.70 to 3.14 ± 0.66 Nm for coordinated motion. The mean relative reductions were 43.05%, 29.73% and 26.62%, respectively. Across matched configurations, R-SYN cut test loss by 23.6%, T-SYN with transferred weights by 9.6%, bone fitting by 10.9%, and wrap geometry fitting by 1.4%. Adding constraint torques raised it by 4%. The baseline median calibration time was 258 s, and wrap fitting added 1708 s on average.

Limitations

The evaluation used one computational arm model and recordings from four healthy men. The metric measures agreement between two calculated torques, and fitting bone parameters can move the inverse dynamics reference itself. R-SYN refits on the test motions, which can absorb some model error. The authors left the effect of calibration movement choice for future work. Code availability and testing on a robotic device were not reported.

Industry impact

Upper-limb exoskeleton and prosthesis developers, as well as rehabilitation software teams, could evaluate the method for personalized fitting in 1 to 3 years. Adoption would require validation in intended users and tasks, independent checks of torque accuracy, and evidence that transferred weights and the fitting workflow perform reliably in routine use.