InterBand-EMG: A Cross-Band Foundation Model for Generalizable Hand-Pose Estimation
This preprint introduces InterBand-EMG, a model that learns to track finger joints from wrist muscle signals. On SynapMyo, it cut mean joint-angle error by 16.2% to 24.2% against the strongest tested baseline across splits that held out users, tasks, or both. The result matters for capturing hand motion when a camera loses sight of the fingers.
Can learning separate frequency-band codes through joint reconstruction improve hand-pose tracking for users and movements held out of training?
Objects can obscure the fingers, and hands can leave a camera's field of view. Wrist electrodes can still measure muscle activity, but differences in anatomy, electrode placement and skin contact make the same movement look different in the signal across people and sessions.
The supervised vemg2pose model learns from paired muscle signals and poses. EMG-GPT pretrains by predicting future codes from a frozen tokenizer, yet its published tracking error exceeded that of vemg2pose on all three emg2pose splits. BandVQ trains separate frequency-band tokenizers for EEG, each reconstructing its own band independently.
InterBand-EMG learns a separate codebook for each of three frequency bands. During spectral reconstruction, each band's codes attend to features from all three. The frozen tokenizer supplies targets for a shared encoder that predicts codes at masked positions in broadband EMG without pose labels. The authors then fine-tune it with a recurrent Transformer that accumulates joint-angle changes from a supplied starting pose. SynapMyo uses eight-channel Waveletech wristbands and maps labels from Manus motion-capture gloves or camera recordings to 20 UmeTrack joint angles.
Both benchmarks use offline tracking on recordings from people, with a supplied initial pose. On emg2pose, which contains approximately 370 hand-hours from 193 participants, mean absolute joint-angle error for User, Stage and User+Stage was 7.28°, 9.70° and 10.00° versus NHN's published 7.30°, 10.12° and 10.16°. The reported reduction was 0.3% to 4.2%, with differences in evaluation protocols. SynapMyo contains 81,564 single-hand recordings totaling 1,227.74 hand-hours from 499 users across 68 movement categories. Under its common protocol, the User, Task and User+Task splits evaluated 50, 395 and 50 users, respectively. Mean absolute joint-angle error was 5.06°, 5.24° and 5.70° versus 6.04°, 6.91° and 6.86° for vemg2pose, a reduction of 16.2% to 24.2%.
The offline tests start from a reference pose. Real-time latency, temporal stability and resilience to wristband repositioning remain unverified. SynapMyo's movement coverage is uneven, and some glove-derived angles capture limited motion detail. Held-out tasks can resemble training tasks. The reconstruction ablations also vary loss objectives and masks, so they cannot isolate the effect of cross-band interaction. The authors plan to release the code and data upon acceptance.
Wearable interface suppliers and robot integrators could pilot EMG-based demonstration capture or teleoperation in 1 to 3 years if streaming tests confirm acceptable latency and stability, tracking survives wristband repositioning, and the system can reliably obtain its starting pose.
The full text is not republished here because the paper's license does not allow it. Read the original on arXiv.