MEKAWIRE
ExpertarXiv

Roboclock: A Unified Benchmark for Time-Aware Robotic Intelligence

Yujie Zhao, Anthony L. Hu, Zimeng Huang, Zhijing Wu, Luobin Wang, Richard Li, Shrivas Sudharsan, Henrik I. Christensen, Jishen Zhao
From the abstract

Time is a fundamental dimension of robotic intelligence: a robot may fail despite physically correct actions if it acts outside a valid time window, responds too slowly to an event, or fails to meet required throughput. Yet existing robotic benchmarks primarily emphasize spatial correctness and logical task completion, largely overlooking the temporal constraints of real-world applications.

From the abstract. Our summary is in progress.

Full paper

Roboclock: A Unified Benchmark for Time-Aware Robotic Intelligence

Yujie Zhao, Anthony L. Hu, Zimeng Huang, Zhijing Wu, Luobin Wang, Richard Li, Shrivas Sudharsan, Henrik I. Christensen, Jishen Zhao

Published under CC BY 4.0. Reproduced with attribution; original at arXiv:2611.32233 (PDF).

Abstract

Time is a fundamental dimension of robotic intelligence: a robot may fail despite physically correct actions if it acts outside a valid time window, responds too slowly to an event, or fails to meet required throughput. Yet existing robotic benchmarks primarily emphasize spatial correctness and logical task completion, largely overlooking the temporal constraints of real-world applications. We present RoboClock, a unified benchmark for time-aware robotic manipulation featuring 60 tasks across five application domains. Directly mirroring these failure modes, RoboClock structures tasks around Three Types of Temporal Constraints: Temporal Window, Event-Reactive, and Throughput. Furthermore, RoboClock incorporates a Latency-Aligned evaluation protocol that continuously advances environment time during model inference and control-interface delays, paired with time-sensitive metrics. Evaluating over 30 methods, we find that the best-performing approach is the trained \pi_{0.5}, yet it achieves only 8.3% temporal success even on Easy-level tasks, with persistent challenges in generalization and transfer. These findings reveal fundamental limitations in current robotic systems and highlight the need to jointly optimize physical competence, temporal reasoning, and execution latency.

Figure 1: Overview of RoboClock. 60 time-critical manipulation tasks across five application domains, evaluated through a general time interface: any agent (VLA, WAM, or VLM agent) receives observations with the environment clock, and its inference latency advances environment time before its action takes effect.

1 Introduction

Time is a fundamental dimension of physical intelligence. Operating in dynamic, continuously evolving environments, embodied agents require not only spatial reasoning and manipulation skills, but also timely decision-making and execution. In the physical world, a correct action becomes futile if delivered too late – a reality reflected in a recent survey of 800 industry leaders [57], where over 75% view sub-100-ms latency as essential for critical robotic applications. Meanwhile, embodied AI has advanced through VLA models, WAMs, and VLM-based agents [11, 66, 21], reaching 98.5% [66] on LIBERO [74] and 68.87% on RoboDojo [18].

Yet a critical gap separates these benchmark triumphs from real-world deployment: physical time. Conventional evaluation protocols typically assess whether a task is eventually completed in the correct logical sequence, decoupling the agent’s computational and actuation speed from environmental dynamics. By implicitly pausing the simulated world during policy computation, this turn-based paradigm artificially inflates task success rates through two unrealistic relaxations: first, it permits agentic systems to exploit evaluation loops via exhaustive trial-and-error recovery, action rollbacks, and repeated invocation retries; second, it accommodates unbounded inference latency, allowing foundation-model policies to extensively deliberate at each step.

Empirical measurements expose the severity of these hidden temporal costs. A recent NVIDIA study reveals that model inference alone can consume up to 97.8% of total execution time in language-model-based policies, stretching a 5.2-second physical demonstration into nearly four minutes [132]; similarly, ORA [133] achieves 83.5% success on LIBERO [74] at the cost of a 13.8-minute median episode duration [133]. Our profiling across RoboClock tasks (Fig. 2) confirms that this overhead diverges starkly across policy families: while the reactive VLA \pi_{0.5} completes episodes in roughly 70 seconds with only 9% spent on inference, inference time surges to 56% for the WAM OpenWAM-\alpha (\sim145 s total) and 78% for the VLM agent Qwen3.8-Flash-Next (\sim285 s total), compounded by repeated failed calls and prolonged periods when the robot stands still. In the real world, time is more than an efficiency metric: agent speed relative to object dynamics decides task success.

Figure 2: Time breakdown per episode across RoboClock tasks.
Table 1: Comparison of temporal robotic benchmarks. \checkmark: supported; \times: not supported; \LEFTcircle: partial or indirect.
  • ReflexVLA (ReflexBench) [19]
    #Tasks
    6
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \LEFTcircle
    Temporal Requirements Throughput Targets
    \times
    Evaluation Inference Delay Included
    \checkmark
    Evaluation Success Breakdown
    \times
  • DynamicManip [73]
    #Tasks
    5+4
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \LEFTcircle
    Temporal Requirements Throughput Targets
    \times
    Evaluation Inference Delay Included
    \checkmark
    Evaluation Success Breakdown
    \times
  • DynamicVLA (DOM) [130]
    #Tasks
    16∗
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \times
    Temporal Requirements Throughput Targets
    \times
    Evaluation Inference Delay Included
    \LEFTcircle
    Evaluation Success Breakdown
    \times
  • DOMINO [34]
    #Tasks
    35
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \times
    Temporal Requirements Throughput Targets
    \times
    Evaluation Inference Delay Included
    \times
    Evaluation Success Breakdown
    \times
  • RoboDyna [71]
    #Tasks
    30
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \checkmark
    Temporal Requirements Throughput Targets
    \times
    Evaluation Inference Delay Included
    \checkmark
    Evaluation Success Breakdown
    \times
  • LIBERO-Industry [117]
    #Tasks
    3†
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \times
    Temporal Requirements Throughput Targets
    \LEFTcircle
    Evaluation Inference Delay Included
    \times
    Evaluation Success Breakdown
    \times
  • SafeManip (v1) [53]
    #Tasks
    50
    Temporal Requirements Execution Windows
    \times
    Temporal Requirements Response Deadlines
    \times
    Temporal Requirements Throughput Targets
    \times
    Evaluation Inference Delay Included
    \times
    Evaluation Success Breakdown
    \times
  • RoboClock (Ours)
    #Tasks
    60
    Temporal Requirements Execution Windows
    \checkmark
    Temporal Requirements Response Deadlines
    \checkmark
    Temporal Requirements Throughput Targets
    \checkmark
    Evaluation Inference Delay Included
    \checkmark
    Evaluation Success Breakdown
    \checkmark

To bridge this gap, we introduce RoboClock, a benchmark of 60 time-constrained manipulation tasks across five application domains and three difficulty levels (Fig. 1a). Temporal parameters draw on manufacturer documentation, empirical studies, sports rules, and public standards where such sources exist. Tasks fall into three primary types (Fig. 1b): (1) Temporal Window, requiring actions within a specified window (e.g., timely film removal from a developer bath) [117]; (2) Event-Reactive, requiring rapid responses to events with randomized onset times (e.g., an emergency stop after a sudden fault warning) [71, 19, 131]; and (3) Throughput, requiring a minimum completion rate (e.g., replenishing a ball feeder to meet repeated demand) [70, 117]. Each task has one primary type and may include secondary temporal constraints (Sec. 4.1).

We introduce a Latency-Aligned evaluation protocol (Fig. 1c) that accounts for model inference and control-interface delays. Observations are timestamped using the environment clock, and environment time advances during model inference before actions take effect. We report physical progress and success under different timing conditions through four metrics: Progress Score (PS), Physical Success Rate (PSR), Temporal Success Rate (TSR), and Latency-Aligned TSR (LTSR) (Fig. 1d).

Using this protocol, we systematically evaluate over 30 representative methods spanning VLAs, WAMs, and VLM agents, revealing distinct limitations across paradigms. VLAs benefit substantially from fine-tuning, yet even the best-performing model achieves only 8.3% LTSR, with limited generalization to unseen tasks. WAMs achieve higher physical success (14.8% PSR) but exhibit greater latency sensitivity, with temporal success dropping from 10.0% to 3.8% when inference latency is included. VLM agents demonstrate strong zero-shot transfer capabilities, achieving up to 19.0% TSR, yet inference latency reduces this to at most 8.2% LTSR. These findings reveal that physical competence, generalization, and real-time responsiveness remain distinct challenges that must be addressed jointly for time-aware robotic intelligence.

Our main contributions are summarized as follows:

  • RoboClock Benchmark. We introduce a time-sensitive robotics benchmark comprising 60 manipulation tasks across five real-world application domains and three difficulty levels, covering three types of temporal constraints: Temporal Window, Event-Reactive, and Throughput.
  • Latency-Aligned Evaluation Framework. We develop a standardized evaluation protocol that accounts for model inference and control delays, with four metrics (PS, PSR, TSR, and LTSR) that summarize physical progress, manipulation success, and temporal compliance with and without inference latency.
  • Systematic Evaluation of Robotic Agent Systems. We systematically evaluate over 30 representative methods spanning VLAs, WAMs, and VLM agents, revealing distinct limitations across paradigms. Fine-tuned VLAs achieve up to 8.3% LTSR but struggle with generalization. VLM agents demonstrate zero-shot transfer capabilities, yet inference latency reduces their temporal success from up to 19.0% to at most 8.2%.

2 Related Work

2.1 End-to-End Policies and Robot Agent Systems

End-to-end policies map multimodal observations to actions with different latency–generalization trade-offs. Autoregressive VLAs, such as RT-2 [17] and OpenVLA [65], transfer web-scale semantic knowledge but incur sequential decoding costs. Flow-matching VLAs, including \pi_{0}/\pi_{0.5} [10, 11], produce continuous action chunks for fast control, while WAMs such as DreamZero [135] and OpenWAM [127, 136] jointly predict future states and actions at greater computational cost.

VLM-based robot agents couple high-level reasoning with learned policies or programmatic executors. Code as Policies [72], VoxPoser [54], and CaP-X [39] respectively generate policies, construct value maps, and orchestrate action tools. Such systems support compositional planning but introduce reasoning and tool-call delays. RoboClock evaluates how these trade-offs affect task-level temporal compliance.

2.2 Robotic Benchmark Evaluation

Standard manipulation benchmarks have progressed from diverse skill learning in RLBench [61] to long-horizon language conditioning in CALVIN [79], lifelong transfer in LIBERO [74], large-scale household tasks in RoboCasa365 [87], and memory-dependent execution in RoBoMME [28]. While Embodied First Exam [126] evaluates coding agents under real-time inference delays, it relies on coarse overall episode budgets. Overall, existing benchmarks prioritize spatial-semantic generalization and physical completion, treating time merely as a generous step limit. They fail to capture fine-grained temporal requirements, where success depends not only on what actions are executed, but strictly on when and how fast they occur.

2.3 Dynamic Robotic Manipulation and Evaluation

Recent efforts have begun exploring time-sensitive manipulation. DOMINO [34], DynamicVLA [130], and LIBERO-Dynamic [100] study policy execution around moving objects, while Real-Time Chunking [12] and ReflexVLA [19] mitigate inference latency for reactive control. At the task level, RoboDyna [71] introduces periodic physical opportunities, LIBERO-Industry [117] models industrial transfer windows, and SafeManip [53] enforces temporal logic for safety.

However, these works often couple timing with environmental dynamics or focus on narrower task setups, with limited separate reporting of physical and temporal success (Tab. 1). In contrast, RoboClock enables a comprehensive evaluation centered on task-level temporal compliance across 60 tasks in five domains. By unifying execution windows, response deadlines, and throughput targets, while supporting timing-only difficulty variation and reporting success with and without inference latency, RoboClock enables comparisons of temporal compliance and latency sensitivity across end-to-end policies and System 1/System 2 agents.

3 Problem Formulation

3.1 Time Model and Latency-Aligned Execution

We separate environment time t from agent wall-clock time \tau to account for inference latency without including hardware-dependent simulator overhead [83, 119] (Fig. 3). We adopt the synchronous, Latency-Aligned action-chunk execution natively supported by official VLA/WAM implementations. Simulation, rendering, and observation-delivery overhead \Delta_{\mathrm{sim},k} affects only \tau. The environment advances at fixed physics steps \Delta t_{\mathrm{phys}}, with commands updated every \Delta t_{\mathrm{ctrl}}. In cycle k, an observation is captured at t_{\mathrm{obs},k} and delivered at \tau_{\mathrm{obs},k}. The policy produces an action chunk at \tau_{\mathrm{out},k}, with inference latency measured as

L_{\mathrm{infer},k}=\tau_{\mathrm{out},k}-\tau_{\mathrm{obs},k}.
(1)

This includes policy-side processing from observation reception to action generation, excluding simulation, rendering, and observation-delivery overhead.

We use a block-and-replay protocol: save the environment state at t_{\mathrm{obs},k} and suspend physics during inference; then restore the state and advance it under previously committed controls for L_{\mathrm{infer},k}+\delta, where \delta is the fixed control-interface delay. The new action chunk takes effect at

t_{\mathrm{act},k}=t_{\mathrm{obs},k}+L_{\mathrm{infer},k}+\delta,
(2)

rounded up to the next control timestep \Delta t_{\mathrm{ctrl}}. After executing N_{\mathrm{act},k} actions at frequency f_{\mathrm{act}}, the next observation is sampled at

t_{\mathrm{obs},k+1}=t_{\mathrm{act},k}+\frac{N_{\mathrm{act},k}}{f_{\mathrm{act}}},
(3)

and the cycle repeats. Execution is thus synchronous: each inference uses the observation after the preceding chunk finishes. During the replayed delay, the scene evolves before the new chunk takes effect, exposing the consequences of acting on a stale observation. With deterministic replay, this preserves physical action timing up to control-step discretization, independently of simulator speed.

Figure 3: Temporal alignment between environment and agent. Environment time t advances with inference, control delay, and actions; simulation overhead \Delta_{\mathrm{sim},k} affects only agent time \tau.

4 Benchmark Design and Construction

Figure 4: Illustrative outcomes under the four metrics in Red-light freeze. Times are relative to red-light onset; H/M/E mark the hard/medium/easy response limits (2/4/8 s), with outcomes evaluated at the easy limit (\Delta t=8 s). Blue and purple timelines show execution with inference paused and with latency advancing environment time, respectively. (1) Physical failure retains partial PS but fails all success criteria. (2) A late stop achieves full PS and physical success (PSR), but fails TSR and LTSR. (3) A stop that is timely only with inference paused satisfies TSR but fails LTSR. (4) A timely stop even with latency satisfies all criteria.

4.1 Three Categories of Temporal Requirements

RoboClock organizes tasks by the temporal requirement that determines whether a physically correct action is useful. Each task belongs to one of three primary categories, set by its main temporal obligation regardless of domain. Any further timed clause (e.g., an overall time limit) is a secondary constraint; temporal success requires all.

(1) Temporal Window: a target event must occur within [t_{s},t_{e}]; early and late actions fail (e.g., closing the faucet while the collected water is inside a target band that the flow crosses in 6/4/2 s). Four windows open at the start or a rule-defined cue, so only t_{e} binds (App. C). (2) Event-Reactive: an unannounced trigger at randomized t_{\mathrm{event}} requires 0\leq t_{\mathrm{act}}-t_{\mathrm{event}}<\Delta t (e.g., pressing the emergency stop within 3 s of a motor-fault warning). (3) Throughput: correct completions must satisfy N/T\geq R_{\min}, with rolling checks for sustained service (e.g., stocking balls for six demands spaced 12 s apart without starvation).

4.2 Benchmark Construction

Domains, scenes, and assets.

Each domain draws timing constraints from its native workflows (laboratory protocols, clinical devices, household cooking and safety, industrial safety, and games) and has dedicated Isaac Sim scenes, e.g., a kitchen built on Lightwheel Kitchen and a hospital ward converted from an artist-made model. Objects are sourced from public repositories (e.g., RoboCasa and Sketchfab) or custom-modeled; each is converted to USD and articulated as needed for manipulation. Effects beyond rigid-body physics, such as indicator color changes or tea steeping, are governed by process models that dynamically update visible geometry and materials. The 60 task scenes use 111 object and fixture models (excluding robots) plus procedural props such as displays, signal lamps, and timers (App. C).

Task design and randomization.

Process quantities follow manufacturer documents, peer-reviewed studies, sports rulebooks, and public standards where a source exists. Of the 42 time-limited tasks, 8 take their easy limit from a documented time; the rest, including all 17 Throughput tasks, are calibrated against a reference controller that keeps at least 20% or 0.3 s of slack at hard (sources and abstractions in App. D). Every task passed human review by domain authors, who verified that its workflow and cue are realistic and its time limits achievable. Three difficulty levels tighten the primary temporal constraint: the window width, response limit, or required rate. Independently of difficulty, each seed uniformly samples object layouts, event onsets, and physical and process parameters from predefined ranges. Because event onsets and latent parameters are revealed solely through visual cues, policies must actively monitor the scene rather than rely on a fixed schedule.

Demonstrations from ground truth.

For each task, a scripted oracle (i) reads the current ground-truth simulator state (poses, contacts, process variables, and logged event onsets) without access to future events; (ii) converts it via inverse kinematics into 16-D joint targets; (iii) schedules motions to satisfy the temporal clauses; and (iv) retains an episode only if the task evaluator confirms both physical and temporal success. Demonstrations are recorded and verify that each task is feasible on time (App. C.1).

Feasibility validation.

The oracle is our feasibility reference: it reads privileged state, so it has no perception latency, but it moves at the rig’s joint speeds and holds its start pose until the cue is shown. Run on seeds 0–9 at every released difficulty level with inference paused, it reaches joint 99.2% physical and temporal success. Human operators also solve the tasks by teleoperation under the same temporal constraints, reaching 100% PSR and 96% TSR, which shows that the tasks are achievable by an agent that perceives the cues and reacts in time.

4.3 Evaluation Metrics

We report four complementary metrics for physical progress and success under different timing conditions (Fig. 4). With inference paused and timing constraints relaxed, PS, following RoboDojo [18], measures progress across ordered physical milestones, assigning 100 only upon reaching the final goal. PSR measures the percentage of episodes that achieve this goal.

TSR measures the percentage of inference-paused episodes that achieve the physical goal while satisfying all temporal constraints (execution windows, response deadlines, throughput targets). LTSR applies the same success criteria in Latency-Aligned mode, where inference latency advances environment time.

5 Experimental Setup

Additional experimental details, a temporal-difficulty study (App. E), and a real-robot pilot (App. L) are provided in the appendix.

Table 2: End-to-end policies on all 60 tasks: released RoboDojo checkpoints and our fine-tuned models (Sec. 5). A/B/C: Temporal Window, Event-Reactive, Throughput; metrics (Sec. 4.3) in %, macro-averaged over tasks; latency on eight A100s. Shaded: fine-tuned; bold/underline: best/second best.
  • Class
    Model
    A
    PSR
    TSR
    LTSR
    B
    PSR
    TSR
    LTSR
    C
    PSR
    TSR
    LTSR
    Overall
    PSR
    TSR
    LTSR
  • Released checkpoints without fine-tuning
  • VLA
    WALL-OSS-1.0-lite [139]
    A
    0.0
    0.0
    0.0
    B
    0.0
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    0.0
    0.0
    0.0
  • Galaxea G0.5 [75]
    2.1
    A
    0.0
    0.0
    0.0
    B
    0.0
    0.0
    0.0
    C
    0.0
    0.0
    0.7
    Overall
    0.0
    0.0
  • No data
    VPP2 [50]
    A
    5.3
    1.6
    0.0
    B
    0.0
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    1.7
    0.5
    0.0
  • WAM
    Awomo-0.5 [7]
    A
    0.0
    0.0
    0.0
    B
    0.0
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    0.0
    0.0
    0.0
  • Released checkpoints and fine-tuned counterparts
  • No data
    \pi_{0.5} [11]
    A
    0.0
    0.0
    0.0
    B
    0.0
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    0.0
    0.0
    0.0
  • No data
    + fine-tuned (ours)
    A
    15.8
    10.5
    5.3
    B
    19.6
    17.5
    16.7
    C
    0.0
    0.0
    0.0
    Overall
    12.8
    10.3
    8.3
  • No data
    X-VLA [141]
    A
    1.6
    0.0
    0.0
    B
    4.6
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    2.3
    0.0
    0.0
  • VLA
    + fine-tuned (ours)
    A
    8.9
    8.4
    6.8
    B
    18.3
    10.0
    6.7
    C
    0.0
    0.0
    0.0
    Overall
    10.2
    6.7
    4.8
  • No data
    InternW0-\Delta [81]
    A
    5.3
    0.0
    0.0
    B
    1.7
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    2.3
    0.0
    0.0
  • No data
    + fine-tuned (ours)
    A
    10.5
    2.1
    1.6
    B
    22.5
    18.3
    4.2
    C
    0.0
    0.0
    0.0
    Overall
    12.3
    8.0
    2.2
  • No data
    OpenWAM-\alpha [127]
    A
    3.7
    0.0
    0.0
    B
    0.0
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    Overall
    1.2
    0.0
    0.0
  • WAM
    + fine-tuned (ours)
    A
    7.4
    3.7
    1.6
    B
    29.6
    20.8
    8.3
    C
    2.4
    1.8
    0.0
    Overall
    14.8
    10.0
    3.8
Table 3: Seen (45 fine-tuning) vs. unseen (15 held-out) tasks, in %. Shaded: fine-tuned; bold/underline: best/second best.
  • \pi_{0.5}
    Seen (45) PSR
    0.0
    Seen (45) TSR
    0.0
    Seen (45) LTSR
    0.0
    Unseen (15) PSR
    0.0
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
  • + fine-tuned (ours)
    Seen (45) PSR
    17.1
    Seen (45) TSR
    13.8
    Seen (45) LTSR
    11.1
    Unseen (15) PSR
    0.0
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
  • X-VLA
    Seen (45) PSR
    0.9
    Seen (45) TSR
    0.0
    Seen (45) LTSR
    0.0
    Unseen (15) PSR
    6.7
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
  • + fine-tuned (ours)
    Seen (45) PSR
    12.7
    Seen (45) TSR
    8.2
    Seen (45) LTSR
    6.0
    Unseen (15) PSR
    2.7
    Unseen (15) TSR
    2.0
    Unseen (15) LTSR
    1.3
  • InternW0-\Delta
    Seen (45) PSR
    2.4
    Seen (45) TSR
    0.0
    Seen (45) LTSR
    0.0
    Unseen (15) PSR
    2.0
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
  • + fine-tuned (ours)
    Seen (45) PSR
    14.9
    Seen (45) TSR
    10.7
    Seen (45) LTSR
    2.9
    Unseen (15) PSR
    4.7
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
  • OpenWAM-\alpha
    Seen (45) PSR
    1.6
    Seen (45) TSR
    0.0
    Seen (45) LTSR
    0.0
    Unseen (15) PSR
    0.0
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
  • + fine-tuned (ours)
    Seen (45) PSR
    19.8
    Seen (45) TSR
    13.3
    Seen (45) LTSR
    5.1
    Unseen (15) PSR
    0.0
    Unseen (15) TSR
    0.0
    Unseen (15) LTSR
    0.0
Table 4: Agent frameworks on Qwen3.8-27B with a shared budget of 100 model calls per episode. Bold/underline: best/second best.
  • PyRUA-Lean [110]
    A PS
    7.4
    A PSR
    5.3
    A TSR
    0.0
    A LTSR
    0.0
    B PS
    5.4
    B PSR
    2.9
    B TSR
    2.5
    B LTSR
    0.0
    C PS
    0.0
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    4.5
    Overall PSR
    2.8
    Overall TSR
    1.0
    Overall LTSR
    0.0
  • RPent [140]
    A PS
    12.1
    A PSR
    5.3
    A TSR
    3.7
    A LTSR
    0.0
    B PS
    7.1
    B PSR
    4.2
    B TSR
    2.5
    B LTSR
    0.0
    C PS
    4.7
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    8.0
    Overall PSR
    3.3
    Overall TSR
    2.2
    Overall LTSR
    0.0
  • HexaShell [42]
    A PS
    11.1
    A PSR
    5.3
    A TSR
    2.1
    A LTSR
    0.0
    B PS
    5.8
    B PSR
    5.4
    B TSR
    2.9
    B LTSR
    0.0
    C PS
    2.9
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    6.7
    Overall PSR
    3.8
    Overall TSR
    1.8
    Overall LTSR
    0.0
  • PhysicalRSI [84]
    A PS
    6.3
    A PSR
    2.1
    A TSR
    0.0
    A LTSR
    0.0
    B PS
    10.4
    B PSR
    10.0
    B TSR
    2.5
    B LTSR
    0.0
    C PS
    2.4
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    6.8
    Overall PSR
    4.7
    Overall TSR
    1.0
    Overall LTSR
    0.0
  • uni-robot-agent [137]
    A PS
    6.3
    A PSR
    5.3
    A TSR
    0.0
    A LTSR
    0.0
    B PS
    7.9
    B PSR
    5.8
    B TSR
    2.5
    B LTSR
    0.0
    C PS
    6.5
    C PSR
    2.4
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    7.0
    Overall PSR
    4.7
    Overall TSR
    1.0
    Overall LTSR
    0.0
  • SenseNova-RoboRSI [108]
    A PS
    16.3
    A PSR
    5.3
    A TSR
    3.7
    A LTSR
    0.0
    B PS
    14.2
    B PSR
    11.3
    B TSR
    2.9
    B LTSR
    0.0
    C PS
    5.9
    C PSR
    2.4
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    12.5
    Overall PSR
    6.8
    Overall TSR
    2.3
    Overall LTSR
    0.0
  • Agent-as-Policy
    A PS
    11.1
    A PSR
    2.6
    A TSR
    2.1
    A LTSR
    0.0
    B PS
    10.8
    B PSR
    10.4
    B TSR
    0.0
    B LTSR
    0.0
    C PS
    1.2
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    8.2
    Overall PSR
    5.0
    Overall TSR
    0.7
    Overall LTSR
    0.0
  • EEF
    A PS
    4.2
    A PSR
    3.2
    A TSR
    2.6
    A LTSR
    0.0
    B PS
    0.8
    B PSR
    0.0
    B TSR
    0.0
    B LTSR
    0.0
    C PS
    0.0
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    1.7
    Overall PSR
    1.0
    Overall TSR
    0.8
    Overall LTSR
    0.0
  • Tool-augmented EEF
    A PS
    23.2
    A PSR
    10.5
    A TSR
    5.3
    A LTSR
    0.0
    B PS
    15.8
    B PSR
    14.6
    B TSR
    10.4
    B LTSR
    2.9
    C PS
    1.8
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    14.2
    Overall PSR
    9.2
    Overall TSR
    5.8
    Overall LTSR
    1.2
Table 5: VLMs on all 60 tasks through Tool-augmented EEF; †open-weight; §text-only reference (GLM-5.3 receives no images). Overall is recomputed from displayed A/B/C means with 19/24/17 task weights. LTSR charges A100 latency with speculative decoding (open-weight; Tab. 10) or API latency. Bold/underline: best/second best.
  • Class
    Model
    A
    PS
    PSR
    TSR
    LTSR
    B
    PS
    PSR
    TSR
    LTSR
    C
    PS
    PSR
    TSR
    LTSR
    Overall
    PS
    PSR
    TSR
    LTSR
  • No data
    Gemini 4 Argon [46]
    A
    41.1
    24.7
    20.5
    10.5
    B
    40.4
    36.3
    24.6
    12.1
    C
    21.8
    7.6
    6.5
    0.0
    Overall
    35.3
    24.5
    18.2
    8.2
  • No data
    Claude Opus 5.5 [5]
    A
    30.5
    17.4
    12.6
    0.0
    B
    30.8
    26.7
    23.8
    2.5
    C
    12.9
    1.2
    0.6
    0.0
    Overall
    25.7
    16.5
    13.7
    1.0
  • No data
    GPT-6 Astra [92]
    A
    43.7
    28.4
    22.1
    5.8
    B
    40.8
    34.6
    30.0
    2.9
    C
    18.8
    0.0
    0.0
    0.0
    Overall
    35.5
    22.8
    19.0
    3.0
  • No data
    GPT-6.1 Sol [91]
    A
    38.9
    27.4
    24.2
    1.6
    B
    37.1
    32.9
    24.2
    4.6
    C
    15.3
    0.0
    0.0
    0.0
    Overall
    31.5
    21.8
    17.3
    2.3
  • No data
    Qwen3.5-4B† [98]
    A
    13.7
    10.5
    2.6
    0.0
    B
    2.9
    2.5
    2.1
    0.0
    C
    0.6
    0.0
    0.0
    0.0
    Overall
    5.7
    4.3
    1.7
    0.0
  • No data
    Qwen3.5-9B† [98]
    A
    13.7
    10.5
    0.0
    0.0
    B
    1.3
    0.4
    0.0
    0.0
    C
    0.0
    0.0
    0.0
    0.0
    Overall
    4.8
    3.5
    0.0
    0.0
  • No data
    Gemma 4 26B-A4B† [47]
    A
    17.9
    10.5
    5.3
    0.0
    B
    9.2
    8.3
    6.3
    2.1
    C
    0.6
    0.0
    0.0
    0.0
    Overall
    9.5
    6.7
    4.2
    0.8
  • No data
    Qwen3.8-27B† [99]
    A
    23.2
    10.5
    5.3
    0.0
    B
    15.8
    14.6
    10.4
    2.9
    C
    1.8
    0.0
    0.0
    0.0
    Overall
    14.2
    9.2
    5.8
    1.2
  • No data
    Muse Glimmer 30B† [80]
    A
    11.1
    7.9
    2.6
    0.0
    B
    6.7
    6.3
    0.0
    0.0
    C
    1.2
    0.0
    0.0
    0.0
    Overall
    6.5
    5.0
    0.8
    0.0
  • No data
    Qwen3.8-Flash-Next† [99]
    A
    17.9
    10.5
    2.6
    0.0
    B
    19.6
    18.8
    12.5
    2.1
    C
    1.2
    0.0
    0.0
    0.0
    Overall
    13.8
    10.8
    5.8
    0.8
  • No data
    DeepSeek V4.1 Flash† [29]
    A
    11.1
    3.2
    2.6
    0.0
    B
    16.3
    14.6
    4.2
    0.0
    C
    1.2
    0.0
    0.0
    0.0
    Overall
    10.3
    6.8
    2.5
    0.0
  • VLM
    GLM-5.3†§ [138]
    A
    5.3
    0.0
    0.0
    0.0
    B
    2.9
    2.5
    2.1
    0.0
    C
    0.0
    0.0
    0.0
    0.0
    Overall
    2.8
    1.0
    0.8
    0.0

The main evaluation protocol uses the easy level of all 60 tasks, with 10 seeds per task for every model. We evaluate two groups of methods and report them separately (Tabs. 2–5): end-to-end policies (VLAs and WAMs) and foundation-model agents (VLMs and agent frameworks).

End-to-end policies.

An end-to-end policy maps the current observation and instruction to actions in a single model call. We cover two classes, VLAs and WAMs, taken from the RoboDojo leaderboard [18], since RoboClock shares its embodiment: WALL-OSS-1.0-lite [139], Galaxea G0.5 [75], \pi_{0.5} [11], and X-VLA [141] as VLAs, and VPP2 [50], Awomo-0.5 [7], InternW0-\Delta [81], and OpenWAM-\alpha [127] as WAMs.

Fine-tuning.

We fine-tune two VLAs (\pi_{0.5} and X-VLA) and two WAMs (OpenWAM-\alpha and InternW0-\Delta) from their released RoboDojo checkpoints on oracle demonstrations from 45 tasks, holding out 15 tasks for generalization evaluation. Every model is trained for three epochs on the same demonstration set. Tab. 2 compares released and fine-tuned checkpoints on all 60 tasks, and Tab. 3 separates seen and held-out tasks; settings are in App. A.1.

VLM agents.

We compare agent configurations using Qwen3.8-27B [99] with a shared budget of 100 model calls per episode (Tab. 4). These include six open frameworks—PyRUA-Lean [110], RPent [140], HexaShell [42], PhysicalRSI [84], uni-robot-agent [137], and SenseNova-RoboRSI [108]—as well as Agent-as-Policy [103], RoboDojo EEF control [18], and Tool-augmented EEF. We use the best-performing Tool-augmented EEF for all VLM backbones. Its tools operate on visual observations and measured robot state, without access to privileged simulator ground truth (App. B).

VLM backbones.

VLMs are queried in closed loop without robot-specific training, using Tool-augmented EEF. We evaluate four proprietary models, Gemini 4 Argon [46], Claude Opus 5.5 [5], GPT-6 Astra [92], and GPT-6.1 Sol [91], and seven open-weight models: Qwen3.5-4B/9B [98], Gemma 4 26B-A4B [47], Qwen3.8-27B and Qwen3.8-Flash-Next [99], Muse Glimmer 30B [80], and DeepSeek V4.1 Flash [29]. As a text-only reference we also run the official GLM-5.3 [138], a language model without image input: it receives the same requests, but the camera images are dropped, so it acts only from the instruction, the measured robot state, and tool feedback. All run with provider-recommended settings and low thinking mode. For LTSR, open-weight models run on eight A100 GPUs with their fastest speculative-decoding configuration; proprietary models are charged their API latency.

6 Results and Ablation Study

6.1 Main Results

All policies and agents share the same low-level 16-D joint-position action interface (Tabs. 2–5).

VLAs and WAMs: training improves success, but generalization remains limited.

The eight released checkpoints achieve at most 2.3% overall PSR and 0.5% TSR, indicating little zero-shot transfer to RoboClock (Tab. 2). Three epochs of task-specific training improve all four models: OpenWAM-\alpha reaches the highest PSR, 14.8% at 10.0% TSR, and \pi_{0.5} the highest TSR, 10.3% at 12.8% PSR, followed by InternW0-\Delta (12.3%, 8.0%) and X-VLA (10.2%, 6.7%). Most gains come from Event-Reactive tasks, where three of the four exceed 17% TSR, while Throughput TSR stays at or below 1.8%. The gains remain on seen tasks: seen-task TSR rises to 8.2–13.8%, but on the 15 held-out tasks only X-VLA reaches nonzero TSR (2.0%; Tab. 3). Demonstrations thus improve execution but barely transfer to unseen tasks.

Inference speed decides how much of these gains survives Latency-Aligned evaluation. The VLAs keep most of their TSR: \pi_{0.5} retains 8.3% LTSR against 10.3% TSR, and X-VLA 4.8% against 6.7%. The slower WAMs lose most of it: OpenWAM-\alpha falls from 10.0% to 3.8% and InternW0-\Delta from 8.0% to 2.2%, so \pi_{0.5} also has the highest LTSR.

VLM agents: zero-shot transfer is constrained by inference latency.

Without robot-specific training, Gemini 4 Argon achieves 24.5% PSR and 18.2% TSR through Tool-augmented EEF, while GPT-6 Astra reaches 22.8% and 19.0% (Tab. 5). For context, GPT-6 Astra’s physical completion rate is close to its 22.48% simulation SR on RoboDojo [102]; the different interfaces preclude a controlled comparison of task difficulty. With inference latency included, Gemini and GPT-6 Astra fall to 8.2% and 3.0% LTSR, GPT-6.1 Sol and Claude Opus 5.5 to 2.3% and 1.0%, and no open-weight VLM exceeds 1.2%. Gemini keeps more of its TSR because it needs fewer turns (a median of 3 against 6 for GPT-6 Astra per successful episode), which brings it close to the fine-tuned \pi_{0.5} (8.3% LTSR); these rates depend on the API serving speed (App. F.1).

Table 6: Single-factor perturbations of Lab training episodes. Before/after: \pi_{0.5} TSR (%), zero latency; \Delta in percentage points. {}^{**}p{<}.01 (exact McNemar). Oracle: 488/490 perturbed episodes solved. With measured latency, later events again reduce TSR (-10.5 points).
  • Lighting
    Tasks
    B1–B7
    n
    70
    Before
    45.7
    After
    45.7
    \Delta
    +0.0
  • Mass, friction
    Tasks
    B1–B7
    n
    70
    Before
    45.7
    After
    44.3
    \Delta
    -1.4
  • Object pose
    Tasks
    B1, B4
    n
    20
    Before
    80.0
    After
    55.0
    \Delta
    -25.0
  • Event earlier
    Tasks
    B1–B7
    n
    32
    Before
    40.6
    After
    46.9
    \Delta
    +6.3
  • Event later
    Tasks
    B1–B7
    n
    38
    Before
    50.0
    After
    10.5
    \Delta
    -39.5^{**}
  • Stated duration
    Tasks
    A5
    n
    20
    Before
    60.0
    After
    0.0
    \Delta
    -60.0^{**}
Table 7: A5: lifts remain near demonstration time (16 s). Times: episode seconds; none: no lift by deadline. †Immersion 0.6 s later, measured-latency rerun.
  • 12 s (trained)
    Required lift
    16.0
    Actual lift
    16.1
    Success
    6/10
  • 9 s
    Required lift
    13.1
    Actual lift
    none
    Success
    0/10
  • 15 s
    Required lift
    19.0
    Actual lift
    16.1
    Success
    0/10
  • 12 s, delayed entry†
    Required lift
    16.6
    Actual lift
    16.3
    Success
    0/10
Fine-tuning relies on the training clock.

We fine-tune \pi_{0.5} on 224 Lab demonstrations with elapsed time in the prompt, then perturb its training episodes (Tab. 6). Lighting and physics barely change TSR; object pose reduces it nonsignificantly by 25 points. Later events reduce TSR from 50.0% to 10.5%, with 66% premature responses; earlier events preserve success. Changing A5’s duration yields zero success: a 15 s instruction still produces a lift at 16.1 s, about 3 s early (Tab. 7). Delayed immersion also causes premature lifting, suggesting reliance on demonstration timing rather than the required waiting interval.

6.2 Ablation: VLM Decode Speed

Figure 5: Effect of decode speed on LTSR. Left axis: LTSR; right axis: completed Throughput jobs; dashed: zero-latency reference.

To isolate decoding latency, we assume speeds of 35–3K tokens/s and compute each query’s delay as its output token count divided by the assumed speed. We add this delay to environment time in closed-loop reruns of GPT-6 Astra and Qwen3.8-Flash-Next (Fig. 5). For GPT-6 Astra, success rises monotonically with speed: overall LTSR grows from 5.7% to 18.0% (Event-Reactive 6.2% to 26.3%, Temporal Window 10.0% to 23.8%) and completed Throughput jobs from 55 to 92. Event-Reactive tasks benefit most, as each call consumes part of their response deadline, and gains diminish beyond 1K tokens/s as LTSR approaches the inference-paused reference. Qwen3.8-Flash-Next (Fig. 5(B)) stays near zero at every speed; its zero-latency reference is already low, so its loss is capability-limited. These results show how our benchmark can guide targeted inference acceleration for VLM agents by identifying where faster decoding improves task success.

6.3 Analysis: Latency Cost Across Policy Families

Figure 6: Latency cost across policy families. (A) TSR and LTSR by inference time per action step. (B) LTSR/TSR ratio; area \propto TSR. Blue: VLA, green: WAM (both fine-tuned), orange: VLM.

Per action step, a 25 Hz policy step for VLAs and WAMs and a 50 Hz control step for VLM tool calls (Fig. 6), only the two VLAs stay within their 40 ms step period, at 4.2 and 9.3 ms, and keep 81% and 72% of their TSR. The other plotted models need 48–147 ms and keep at most 38% (OpenWAM-\alpha at 51 ms); the proprietary VLMs keep at most 16% despite the highest TSRs.

6.4 Failure Case Study

Figure 7: Titration task. Close the stopcock (dashed box) when the solution turns pale pink, after 18–20 mL of NaOH.

Fig. 7 shows one titration task failed in three ways: Claude Opus 5.5 knocks the lever shut after 0.7 of the required 18 mL; GPT-6 Astra closes it at 60.4 s, after the flask has turned strongly pink; and in another Opus episode, the trigger fires on time but the grasp misses the lever. Our evaluation distinguishes these outcomes by relating physical completion to the cue and valid time window: the first two close the lever outside the window, whereas the third fails to execute a timely response. These traces suggest different interventions—better cue-conditioned action selection, shorter response delays, and more reliable manipulation—showing how RoboClock can guide improvements beyond a single success score.

7 Discussion and Limitations

Fine-tuned VLAs offer fast execution but limited transfer, while VLM agents generalize better but lose most temporal success to inference delay. These complementary strengths motivate coupling a VLM planner with a learned VLA/WAM controller. Through latency sweeps and failure analysis, RoboClock can guide targeted improvements in inference speed, timing decisions, and manipulation reliability. Our evaluation uses simulation with simplified processes and some compressed time scales, so transfer to physical robots remains to be validated. LTSR also depends on inference hardware and serving conditions, which should be considered when comparing systems.

8 Conclusion

We introduced RoboClock, a benchmark of 60 manipulation tasks with Temporal Window, Event-Reactive, and Throughput requirements, evaluated under a Latency-Aligned protocol that reports physical completion and temporal compliance with and without inference latency. Fine-tuned policies improve on familiar tasks but rarely transfer, while VLM agents transfer but struggle with latency, motivating generalizable agents with temporal reasoning and fast execution.

LLM Usage Statement

We used OpenAI Codex and Anthropic Claude Code to assist with code implementation and debugging, and OpenAI ChatGPT and Google Gemini for language editing to improve the clarity and readability of the manuscript. All experimental results were obtained from actual experimental runs and were not generated or fabricated by LLMs. The authors reviewed and verified the implementations, experimental results, and scientific conclusions, and take full responsibility for the content of this work.

References

  1. [1] 3M Hot Melt Adhesive 3764, Technical Data Sheet. 3M, 2016. Revision July 2016, reseller-hosted copy. Accessed 2026-11-16.
  2. [2] Adam Equipment. CBC series counting scale manual, specifications, n.d. Accessed 2026-11-24.
  3. [3] American College of Surgeons. May is national Stop the Bleed month: Learn how to save a life with three simple actions. Press release, 2025. “A person can die from severe blood loss in as little as five minutes.” Accessed 2026-11-20.
  4. [4] Speed Cups: Game Rules (No. 01880). AMIGO Spiel + Freizeit GmbH, n.d. Accessed 2026-11-16.
  5. [5] Anthropic. Claude Opus 5.5. API model claude-opus-5-5, 2026.
  6. [6] Checkweighing: Selecting the Right Checkweigher, White Paper. Avery Weigh-Tronix (Illinois Tool Works), 2022. Accessed 2026-11-24.
  7. [7] Awomo-WAM Team. Awomo-0.5 technical report. Technical report, Westlake University, 2026.
  8. [8] Karin M. Bausenhart and Rolf Ulrich. What is prepared in temporal preparation? A review and a historical appreciation. Frontiers in Psychology, 17:1768431, 2026.
  9. [9] BDVWA. Leak calculator (60 psi line pressure), n.d. Water utility table. Accessed 2026-11-16.
  10. [10] Kevin Black, Noah Brown, Danny Driess, et al. \pi_{0}: A vision-language-action flow model for general robot control. arXiv preprint arXiv:2410.24164, 2024.
  11. [11] Kevin Black, Noah Brown, James Darpinian, et al. \pi_{0.5}: A vision-language-action model with open-world generalization. In Conference on Robot Learning, 2025a.
  12. [12] Kevin Black, Manuel Y. Galliker, and Sergey Levine. Real-time execution of action chunking flow policies. In Advances in Neural Information Processing Systems, 2025b.
  13. [13] Whac-A-Mole FEC Operation and Service Manual, BSR V1.0. Bob’s Space Racers, n.d. Programming options “PD Start Head Up Time”. Accessed 2026-11-16.
  14. [14] Bostik. Criteria for selecting a corrugated packaging adhesive. Bostik blog, 2017. Accessed 2026-11-24.
  15. [15] Brewers Association Technical Committee. Draught beer quality manual. Second edition, Brewers Association, Boulder, CO, 2011. Section “Dispense Goals”. Accessed 2026-11-24.
  16. [16] William Bridges. LOPA and human reliability – human errors and human IPLs. In AIChE 6th Global Congress on Process Safety, 2010. Accessed 2026-11-16.
  17. [17] Anthony Brohan, Noah Brown, Justice Carbajal, et al. RT-2: Vision-language-action models transfer web knowledge to robotic control. In Conference on Robot Learning, 2023.
  18. [18] Tianxing Chen, Yue Chen, Zixuan Li, et al. RoboDojo: A unified sim-and-real benchmark for comprehensive evaluation of generalist robot manipulation policies. arXiv preprint arXiv:2607.04434, 2026a.
  19. [19] Yuxuan Chen, Wanruo Zhang, and Xiao Li. Reflex: Enabling fast and predictive vision-language-action models for reaction-critical manipulation. arXiv preprint arXiv:2608.14379, 2026b.
  20. [20] Christopher J. Chin, Leigh J. Sowerby, Ava John-Baptiste, and Brian W. Rotenberg. Reducing otolaryngology surgical inefficiency via assessment of tray redundancy. Journal of Otolaryngology – Head & Neck Surgery, 43(1):46, 2014. Central processing tray-build records (39 trays, 4541 builds): “The average time to pack one instrument was 17.7 seconds” (7.6–31.6 s, 2.5th–97.5th percentiles). Accessed 2026-11-24.
  21. [21] Zhaoyang Chu, Earl T. Barr, Claire Le Goues, et al. OpenRUA: Robot-use agents are zero-shot visuomotor policies. arXiv preprint arXiv:2610.02459, 2026.
  22. [22] Cisco-Eagle. Order picking velocity: Storage and picking method comparisons, 2018. Material-handling integrator article. Accessed 2026-11-16.
  23. [23] Conveyor Buyers Guide. Cisco-Eagle, n.d. p. 5, Conveyor speed calculation. Accessed 2026-11-16.
  24. [24] Cockeyed.com. How much time does a dishwasher save?, n.d. Accessed 2026-11-24.
  25. [25] Ángel Correa, Juan Lupiáñez, and Pío Tudela. The attentional mechanism of temporal orienting: Determinants and attributes. Experimental Brain Research, 169(1):58–68, 2006.
  26. [26] Nikolaus Correll, Kostas E. Bekris, Dmitry Berenson, Oliver Brock, Albert Causo, Kris Hauser, Kei Okada, Alberto Rodriguez, Joseph M. Romano, and Peter R. Wurman. Analysis and observations from the first Amazon Picking Challenge. IEEE Transactions on Automation Science and Engineering, 15(1):172–188, 2018.
  27. [27] Puritan Bennett 800 Series Ventilator System: Operator’s and Technical Reference Manual. Covidien, 2014. Part No. 10067720 Rev. D. Apnea interval: range 10 to 60 s, new-patient value 20 s (adult), 15 s (pediatric), 10 s (neonatal). Accessed 2026-11-20.
  28. [28] Yinpei Dai, Hongze Fu, Jayjun Lee, Yuejiang Liu, Haoran Zhang, Jianing Yang, Chelsea Finn, Nima Fazeli, and Joyce Chai. RoboMME: Benchmarking and understanding memory for robotic generalist policies. arXiv preprint arXiv:2603.04639, 2026.
  29. [29] DeepSeek-AI. DeepSeek V4.1 Flash. Open-weight model, 2026.
  30. [30] Dorner. Stainless steel gravity roller conveyor. Product specification sheet 615c. Accessed 2026-11-24.
  31. [31] James T. Eckner, David B. Lipps, Hogene Kim, James K. Richardson, and James A. Ashton-Miller. Can a clinical test of reaction time predict a functional head-protective response? Medicine & Science in Sports & Exercise, 43(3):382–387, 2011.
  32. [32] R. Scott Evans, Kyle V. Johnson, Vrena B. Flint, Tupper Kinder, Charles R. Lyon, William L. Hawley, David K. Vawdrey, and George E. Thomsen. Enhanced notification of critical ventilator events. Journal of the American Medical Informatics Association, 12(6):589–595, 2005. Table 3, four ICUs, 2004-10 to 2005-03: critical alarms for unintended disconnection lasted 23.3 s on average (range 10–55 s). Accessed 2026-11-20.
  33. [33] Patrik Fager, Martina Calzavara, and Fabio Sgarbossa. Modelling time efficiency of cobot-supported kit preparation. International Journal of Advanced Manufacturing Technology, 106(5–6):2227–2241, 2020.
  34. [34] Heng Fang, Shangru Li, Shuhan Wang, Xuanyang Xi, Dingkang Liang, and Xiang Bai. Towards generalizable robotic manipulation in dynamic environments. arXiv preprint arXiv:2603.15620, 2026.
  35. [35] FIDE Laws of Chess (effective 1 January 2023). Fédération Internationale des Échecs (FIDE), 2023. Glossary “increment” and “cumulative (Fischer) mode”. Accessed 2026-11-16.
  36. [36] Regulations for the FIDE World Rapid & Blitz Championships 2025. Fédération Internationale des Échecs (FIDE), 2025. Arts. 4.2.2.1 and 4.3.1.2.1. Accessed 2026-11-24.
  37. [37] Mitchell James Finlay et al. Test-retest reliability and sensitivity of senior elite amateur boxers maximal punch force, as quantified by a vertically mounted force plate. PLOS ONE, 18(8):e0289791, 2023.
  38. [38] Christopher J. Forgaard, Ian M. Franks, Dana Maslovat, and Romeo Chua. Perturbation predictability can influence the long-latency stretch response. PLOS ONE, 11(10):e0163854, 2016. “To prevent anticipation of a perturbation, most studies have used variable foreperiods”. Accessed 2026-11-24.
  39. [39] Letian Fu, Justin Yu, Karim El-Refai, et al. CaP-X: A framework for benchmarking and improving coding agents for robot manipulation. In International Conference on Machine Learning, 2026.
  40. [40] K. Fukaya. Special research report RIIS-SRR-No.13, chapter 5. Technical report, Research Institute of Industrial Safety, Japan, 1993. Accessed 2026-11-16.
  41. [41] Jonathan Gagné. The struggle for a steady kettle flow. Coffee ad Astra (blog), 2020. Accessed 2026-11-16.
  42. [42] Hongcheng Gao, Jianshu Zeng, Alex Zhou, Shijia Ge, Xuan Shangguan, et al. HexaShell: A universal harness for robot coding agents in simulation and the real world. arXiv preprint arXiv:2610.23479, 2026.
  43. [43] Alexandra Garnier, Pascal Bonnabry, and Lucie Bouchoud. Using simulation to improve pharmacy operators’ handling of cytotoxic spills. Journal of Oncology Pharmacy Practice, 31(3):355–363, 2025. Surprise test with a broken fake cytotoxic vial, 12 operators: mean time to handle the spill 17.3 min (SD 3.6) before and 11.9 min (SD 1.5) after training. Accessed 2026-11-20.
  44. [44] Electric Actuators EA15–EA250, Data Sheet. Georg Fischer Piping Systems, n.d. Accessed 2026-11-16.
  45. [45] Karen K. Giuliano. IV smart pumps: The impact of a simplified user interface on clinical use. Biomedical Instrumentation & Technology, 49(s4):13–21, 2015. Critical-care nurses, simulation lab, five programming tasks on three pumps. Task 2, antibiotic as secondary infusion, mean time after training 26.5 (pump C), 36.6 (A), 58.8 s (B); before training 52.6, 86.2, 101.2 s. Accessed 2026-11-24.
  46. [46] Google. Gemini 4 Argon. API model gemini-4-argon, 2026.
  47. [47] Google DeepMind. Gemma 4 model card: Gemma-4-26B-A4B. https://huggingface.co/google/gemma-4-26B-A4B-it, 2026.
  48. [48] Marc Green. “How long does it take to stop?” Methodological analysis of driver perception-brake times. Transportation Human Factors, 2(3):195–216, 2000. Values read in the author’s summary, https://visualexpert.com/Resources/reactiontime.html, accessed 2026-11-24.
  49. [49] Guinness World Records. Fastest sport stacking individual cycle (WSSA, male), 2024. 4.739 s, 20 July 2024. Accessed 2026-11-16.
  50. [50] Yanjiang Guo, Haodong Yan, Zhide Zhong, Zhongru Zhang, Qingyuan Yang, et al. Video Prediction Policy 2: Predict better, act better. arXiv preprint arXiv:2610.10270, 2026.
  51. [51] Tianfang Han and Robert W. Proctor. Revisiting variable-foreperiod effects: evaluating the repetition priming account. Attention, Perception, & Psychophysics, 84(4):1193–1207, 2022.
  52. [52] Martin G. Helander and Mark H. Karwan. Human motor reactions to dangerous motions in robot operations. Technical Report NTIS PB87-222196, Department of Industrial Engineering, State University of New York at Buffalo, 1987. Accessed 2026-11-24.
  53. [53] Chengyue Huang, Khang Vo Huynh, Sebastian Elbaum, Zsolt Kira, and Lu Feng. SafeManip: A property-driven benchmark for temporal safety evaluation in robotic manipulation. arXiv preprint arXiv:2605.12386v1, 2026.
  54. [54] Wenlong Huang, Chen Wang, Ruohan Zhang, Yunzhu Li, Jiajun Wu, and Li Fei-Fei. VoxPoser: Composable 3D value maps for robotic manipulation with language models. In Conference on Robot Learning, 2023.
  55. [55] Yongqiang Huang, Juan Wilches, and Yu Sun. Robot gaining accurate pouring skills through self-supervised learning and generalization. arXiv:2011.10150, 2020.
  56. [56] E2190 InfinityPACK Hot Melt Adhesive, Technical Data Sheet. Infinity Bond, n.d. Accessed 2026-11-16.
  57. [57] Intel. Six in 10 leaders bet big on robots. only four in 10 are ready, 2026.
  58. [58] Official Basketball Rules 2026, Version 1.1. International Basketball Federation (FIBA), 2026a. Art. 29.2.7 and Art. 44.2.3. Accessed 2026-11-16.
  59. [59] IPF Technical Rulebook, effective 1 March 2026. International Powerlifting Federation, 2026b. Spotter/loader rules. Accessed 2026-11-16.
  60. [60] DM Series Options and Accessories: Electromagnetic Brakes. Interroll, 2025. Data sheet, p. 138. Accessed 2026-11-24.
  61. [61] Stephen James, Zicong Ma, David Rovick Arrojo, and Andrew J. Davison. RLBench: The robot learning benchmark and learning environment. IEEE Robotics and Automation Letters, 2020.
  62. [62] R. Joshi, H. van de Mortel, L. Feijs, P. Andriessen, and C. van Pul. The heuristics of nurse responsiveness to critical patient monitor and ventilator alarms in a private room neonatal intensive care unit. PLoS ONE, 12(10):e0184567, 2017. Video, about 6000 critical alarms: with the nurse outside the room, 26 % answered within 90 s, median response 55 s (IQR 37–70 s); desaturations were over 50 % of alarms. Accessed 2026-11-20.
  63. [63] Matthew Kelm and Udobi Campbell. Improved arrangement and capacity for medication transactions: A pilot study to determine the impact of new technology on medication storage and accessibility. Hospital Pharmacy, 53(5):338–343, 2018. Automated dispensing cabinet: restock time 11.5 s before and 21.3 s after optimization; nurse retrieval 10.5 and 10.3 s per transaction. Accessed 2026-11-24.
  64. [64] Diellza Kelmendi, Florian Miftari, Kastriot Shaqiri, and Tringa Dedi. Kinematic analysis of basketball free throw trajectory. Sport Mont, 23(2):109–114, 2025.
  65. [65] Moo Jin Kim, Karl Pertsch, Siddharth Karamcheti, et al. OpenVLA: An open-source vision-language-action model. In Conference on Robot Learning, 2025.
  66. [66] Moo Jin Kim, Yihuai Gao, Tsung-Yi Lin, et al. Cosmos Policy: Fine-tuning video models for visuomotor control and planning. In International Conference on Learning Representations, 2026.
  67. [67] 12 Litre Drip Tray with Raised Ridges. Kingfisher Direct, 2026. Product page. Accessed 2026-11-16.
  68. [68] Rebecca Knibb and Kirsty Morton. Accuracy in use of adrenalin auto-injectors in a simulated emergency situation: a comparison of JEXT, EpiPen and Emerade. Clinical and Translational Allergy, 5(Suppl 3):O5, 2015. Meeting abstract. 90 untrained adults, trainer pens, simulated emergency with an actor patient: mean time to administer adrenalin Emerade 14.73 s, JEXT 29.21 s, EpiPen 33.72 s; successful administration after reading the instructions 100 %, 64 % and 33 %. Accessed 2026-11-20.
  69. [69] Raimund Lechner, Amelie Oberst, Yannick Beres, Benjamin Mayer, Martin Kulla, Björn Hossfeld, and Holger Gässler. COMBAT-C: COntrol of major bleeding by application of tourniquets over clothing. BMC Emergency Medicine, 24(1):90, 2024. HapMed thigh tourniquet trainer, two experienced providers, undressed setting, Combat Application Tourniquet: application time 24 \pm 4 s (stopped when the windlass was secured), simulated blood loss 99 \pm 17 mL. Accessed 2026-11-20.
  70. [70] Zhuofan Li, Hongkun Yang, Zhenyang Chen, Yangxuan Chen, Yingyan Lin, and Chaojian Li. From inference efficiency to embodied efficiency: Revisiting efficiency metrics for vision-language-action models. arXiv preprint arXiv:2603.19131, 2026a.
  71. [71] Zhiyuan Li, Ruiheng Yang, Xuan Zhao, and Amir Rasouli. Benchmarking robotic manipulation under physically realistic dynamics. In NeurIPS 2026 Workshop on Robot Learning with World Models, 2026b.
  72. [72] Jacky Liang, Wenlong Huang, Fei Xia, Peng Xu, Karol Hausman, Brian Ichter, Pete Florence, and Andy Zeng. Code as Policies: Language model programs for embodied control. arXiv preprint arXiv:2209.07753, 2022.
  73. [73] Haoran Liao, Pengyue Wang, Shuoyu Chen, et al. DynamicManip: Enabling dynamic manipulation from a single static demonstration. arXiv preprint arXiv:2608.01452, 2026.
  74. [74] Bo Liu, Yifeng Zhu, Chongkai Gao, Yihao Feng, Qiang Liu, Yuke Zhu, and Peter Stone. LIBERO: Benchmarking knowledge transfer for lifelong robot learning. In Advances in Neural Information Processing Systems, 2023.
  75. [75] Yicheng Liu, Zibin Dong, Baijun Ye, Tianyuan Yuan, Tao Jiang, et al. G0.5: One autoregressive stream for robot reasoning and action. arXiv preprint arXiv:2608.11739, 2026.
  76. [76] Lobster Elite One, Two & Three Owner’s Manual. Lobster Sports, n.d. Feed interval 2–12 s. Accessed 2026-11-16.
  77. [77] Tensing Maa, Daniel J. Scherzer, Ilana Harwayne-Gidansky, Tali Capua, David O. Kessler, Jennifer L. Trainor, Priti Jani, Becky Damazo, Kamal Abulebda, Maria Carmen G. Diaz, et al. Prevalence of errors in anaphylaxis in kids (PEAK): A multicenter simulation-based study. Journal of Allergy and Clinical Immunology: In Practice, 8(4):1239–1246.e3, 2020. 37 in-situ simulations in 28 institutions: median time to epinephrine 95 s (IQR 77–252) with an auto-injector, 263 s (IQR 146–407.5) when prepared manually. Abstract consulted. Accessed 2026-11-20.
  78. [78] Virgil Mathiowetz, Gloria Volland, Nancy Kashman, and Karen Weber. Adult norms for the Box and Block Test of manual dexterity. American Journal of Occupational Therapy, 39(6):386–391, 1985. Norm table read at https://www.sralab.org/rehabilitation-measures/box-and-block-test, accessed 2026-11-24.
  79. [79] Oier Mees, Lukas Hermann, Erick Rosete-Beas, and Wolfram Burgard. CALVIN: A benchmark for language-conditioned policy learning for long-horizon robot manipulation tasks. IEEE Robotics and Automation Letters, 7(3):7327–7334, 2022.
  80. [80] Meta Superintelligence Labs. Muse Glimmer: Open-weight 30B multimodal agentic model. https://huggingface.co/meta-models/Muse-Glimmer-30B, 2026.
  81. [81] Xingyu Miao, Zizun Li, Baole Fang, Kaiwen Song, Tenghui Wang, et al. InternW0-\Delta: A world action model bridging predictive dynamics and actions with 20K+ hours of open data. arXiv preprint arXiv:2609.31394, 2026.
  82. [82] Technical Manual: Inquisit Whack-A-Mole Test (Keyboard). Millisecond Software, 2026. Go/no-go task after Casey et al. (1997). Accessed 2026-11-16.
  83. [83] Mayank Mittal, Pascal Roth, James Tigue, et al. Isaac Lab: A GPU-accelerated simulation framework for multi-modal robot learning. arXiv preprint arXiv:2511.04831, 2025.
  84. [84] MMLab and PhysicalRSI contributors. Physical RSI 1.0: Recursive self-harness for scaling embodied skills. https://github.com/PhysicalRSI/PhysicalRSI, 2026.
  85. [85] Marnix Naber, Maryam Vaziri Pashkam, and Ken Nakayama. Unintended imitation affects success in a competitive game. Proceedings of the National Academy of Sciences, 110(50):20046–20050, 2013.
  86. [86] NACS. Annual drive-thru report released—QSRs are getting faster. NACS Daily, 1 March 2024, reporting the 2023 Intouch Insight Drive-Thru Study, 2024. Accessed 2026-11-24.
  87. [87] Soroush Nasiriany, Sepehr Nasiriany, Abhiram Maddukuri, and Yuke Zhu. RoboCasa365: A large-scale simulation framework for training and benchmarking generalist robots. In International Conference on Learning Representations, 2026.
  88. [88] B. Ronan O’Driscoll, Luke S. Howard, John Earis, and Vince Mak. British Thoracic Society guideline for oxygen use in adults in healthcare and emergency settings. BMJ Open Respiratory Research, 4(1):e000170, 2017. Tables 2–3: nasal cannulae 2–6 L/min or simple face mask 5–10 L/min; target saturation 94–98 %. W3: saturation observed for at least 5 min after starting or increasing oxygen. Accessed 2026-11-20.
  89. [89] Ranger 3000 Compact Bench Scales, Data Sheet. OHAUS, n.d. Reseller-hosted copy. Accessed 2026-11-24.
  90. [90] BVP80/BVE80 Pneumatic and Electric Actuated Ball Valves. Omega Engineering, n.d. Data sheet. Accessed 2026-11-16.
  91. [91] OpenAI. GPT-6.1 Sol. API model, 2026a.
  92. [92] OpenAI. GPT-6 Astra. API model gpt-6-astra, 2026b.
  93. [93] PHC. MDF-DU700ZHA-PA FrostLess ultra-low temperature freezer: Operating instructions. Manufacturer manual, distributor-hosted, 2023. Accessed 2026-11-16.
  94. [94] HeartStart FRx Defibrillator: Specifications. Philips Healthcare, n.d. Manufacturer data sheet, reseller-hosted. Accessed 2026-11-16.
  95. [95] Barry A. Piorkowski, Adrian Lees, and Gabor J. Barton. Single maximal versus combination punch kinematics. Sports Biomechanics, 10(1):1–11, 2011. Author manuscript.
  96. [96] Pololu Robotics and Electronics. Product 3043: Frequently asked questions (motor stalls). Manufacturer FAQ, 2026. Accessed 2026-11-16.
  97. [97] R. S. H. Pumphrey. Lessons for management of anaphylaxis from a study of fatal reactions. Clinical and Experimental Allergy, 30(8):1144–1150, 2000. UK register of fatal anaphylaxis: “The median time to respiratory or cardiac arrest was 30 min for foods, 15 min for venom and 5 min for iatrogenic reactions.” Abstract consulted. Accessed 2026-11-20.
  98. [98] Qwen Team. Qwen3.5: Model cards for Qwen3.5-4B and Qwen3.5-9B. https://huggingface.co/collections/Qwen/qwen35, 2026a.
  99. [99] Qwen Team. Qwen3.8: Model cards for Qwen3.8-27B and Qwen3.8-Flash-Next. https://huggingface.co/Qwen/Qwen3.8-27B, 2026b.
  100. [100] Shaojie Ren, Jingwen Sun, Zezhi Liu, Hongjin Chen, Xin Jin, Wei Zou, and Zhibo Chen. LIBERO-Dynamic: Benchmarking robotic manipulation in dynamic environments. arXiv preprint arXiv:2610.24579, 2026.
  101. [101] Resuscitation Council UK. Emergency treatment of anaphylaxis: Guidelines for healthcare providers, 2021. May 2021. “Adrenaline is the first-line treatment for anaphylaxis. Give intramuscular (IM) adrenaline early (in the anterolateral thigh)”; “Repeat IM adrenaline after 5 minutes” if problems persist. Accessed 2026-11-20.
  102. [102] RoboDojo Team. RoboDojo simulation leaderboard. https://robodojo-benchmark.com/leaderboard, 2026. Accessed November 17, 2026. GPT-6 Astra: average success rate 22.48%, direct EEF control.
  103. [103] RoboProbe contributors. RoboProbe: An agentic robot manipulation codebase for LLM-as-policy. https://github.com/RoboProbe/RoboProbe, 2026.
  104. [104] cobas p 512 Pre-Analytical System: Technical Specifications. Roche Diagnostics, n.d. Manufacturer sales sheet. Accessed 2026-11-16.
  105. [105] Someshwar Roy and Yael Edan. Givers & receivers perceive handover tasks differently: Implications for human-robot collaborative system design. arXiv:1708.06207, 2017.
  106. [106] S. Rudy. Aluminum finishing: the zincating facts. Finishing and Coating, 2024. Accessed 2026-11-16.
  107. [107] Nuttakarn Runnarong, Jarugool Tretriluxana, Watinee Waiyasil, Preeyanuch Sittisupapong, and Suradej Tretriluxana. Age-related changes in reach-to-grasp movements with partial visual occlusion. PLoS ONE, 14(8):e0221320, 2019.
  108. [108] SenseNova Team. SenseNova-RoboRSI: A unified framework for building, evaluating, and recursively improving embodied agents. https://github.com/OpenSenseNova/SenseNova-RoboRSI, 2026.
  109. [109] Shirley Ryan AbilityLab. Box and block test. Rehabilitation Measures Database, n.d. Adult norms from Mathiowetz et al. (1985). Accessed 2026-11-24.
  110. [110] Ruiyang Si, Jianxin Bi, Shunyu Yang, Rui Ni, Wenbo Huang, et al. Fewer tokens, better action: GPT-6 Astra robot agents with 14% higher success rate but 65% fewer tokens. arXiv preprint arXiv:2610.01939, 2026.
  111. [111] Siemens Healthineers. Atellica task targeted automation. Manufacturer product page, 2026. Accessed 2026-11-16.
  112. [112] Siemens Healthineers. Atellica task targeted automation, n.d. Manufacturer web page. Accessed 2026-11-16.
  113. [113] F. Estelle R. Simons, Janet R. Roberts, Xiaochen Gu, and Keith J. Simons. Epinephrine absorption in children with a history of anaphylaxis. Journal of Allergy and Clinical Immunology, 101(1):33–37, 1998. 0.3 mg intramuscularly from an auto-injector: maximum plasma concentration at a mean 8 \pm 2 min (six of eight children by 5 min); subcutaneously 34 \pm 14 min. Abstract consulted. Accessed 2026-11-20.
  114. [114] Mathilde Stærk, Kasper G. Lauridsen, Julie Niklassen, Rasmus Philip Nielsen, Kristian Krogh, and Bo Løfgren. Barriers and facilitators for successful AED usage during in-situ simulated in-hospital cardiac arrest. Resuscitation Plus, 10:100257, 2022.
  115. [115] STERIS. Instrument processing professional services, n.d. Vendor web page (case figures). Accessed 2026-11-16.
  116. [116] Scott Stone. A quick guide to order picking methods & productivity. Cisco-Eagle blog, 2014. Rates from Carter & Burgess analysis projects. Accessed 2026-11-24.
  117. [117] Ming Shin Cindy Sung, Leijiahao Duan, Haoxiang Wang, Boning Tan, Liangna Fu, Chao Tan, Yafu Li, Yulong Chen, Chaoqun Wan, Zhen Huang, Shuxian Liang, and Xian-Sheng Hua. LIBERO-Industry: Benchmarking robotic manipulation under industrial process constraints, 2026.
  118. [118] Tomoki Takase et al. Evaluating the safety and efficiency of robotic dispensing systems. Journal of Pharmaceutical Health Care and Sciences, 8:24, 2022.
  119. [119] Stone Tao, Fanbo Xiang, Arth Shukla, et al. ManiSkill3: GPU parallelized robotics simulation and rendering for generalizable embodied AI. arXiv preprint arXiv:2410.00425, 2024.
  120. [120] Thermo Fisher Scientific. External monitoring of ultra-low temperature freezers (technical note TNULTEXTMONITOR 1119). Manufacturer technical note, 2019. Accessed 2026-11-16.
  121. [121] United States Pharmacopeia. General chapter \langle 800\rangle hazardous drugs—handling in healthcare settings, 2020. Official 2020-07-01. “Spills must be contained and cleaned immediately only by qualified personnel with appropriate PPE.” Accessed 2026-11-20.
  122. [122] US Patent 5,182,006. Zincate solutions for treatment of aluminum and aluminum alloys, 1993. Accessed 2026-11-16.
  123. [123] Roland van den Tillaar, Vidar Andersen, and Atle Hole Saeterbakken. The existence of a sticking region in free weight squats. Journal of Human Kinetics, 42:63–71, 2014.
  124. [124] EpiPen and EpiPen Jr (epinephrine injection) Auto-Injector: Prescribing Information, Patient Information and Instructions for Use. Viatris / U.S. Food and Drug Administration, 2026. Revised 3/2026. Sec. 2.2: “Firmly push the orange tip of the auto-injector against the outer thigh and hold in place for 3 seconds”; anterolateral thigh, “through clothing if necessary”; tip “at a 90∘ angle (perpendicular) to the thigh”; errors listed: activating upside down, a site other than the outer thigh, “failing to hold the auto-injector in place for a full 3 seconds”. Accessed 2026-11-20.
  125. [125] Piper Wall, Charisse Buising, and Sheryl Sahr. Review: Getting tourniquets right = getting tourniquets tight. Journal of Special Operations Medicine, 19(3):52, 2019. Fig. 1: “One windlass turn = a single 180∘ rotation of the windlass rod”; “only one or possibly two 180∘ turns of the windlass will be required to achieve arterial occlusion. The windlass rod must be secured in the windlass securing clip by the applier at a rotation beyond that at which bleeding is stopped”. Accessed 2026-11-20.
  126. [126] Kangrui Wang, Qineng Wang, Changhe Chen, Pingyue Zhang, Chi Gui, Feishi Wang, Canyu Chen, Wenli Xiao, Xiaoyu Huang, Tonghe Zhang, Linjie Li, Zihan Wang, Minyeong Kim, Yiyou Sun, Mingkai Deng, Jinyu Hou, Qi Zhu, Han Liu, Eric P. Xing, Huaxiu Yao, Zhiwen Fan, Yuejiang Liu, Dawn Song, Pieter Abbeel, Li Fei-Fei, Jiajun Wu, Yuke Zhu, Guanya Shi, Ruohan Zhang, and Manling Li. Embodied First Exam, 2026a.
  127. [127] Yuran Wang, Siqiao Huang, Mingleyang Li, Chenhao Zhang, Jiaqi Liang, et al. OpenWAM: An open, modular exploration towards systematic world-action model pretraining. arXiv preprint arXiv:2609.07398, 2026b.
  128. [128] Scott D. Weingart and Richard M. Levitan. Preoxygenation and prevention of desaturation during emergency airway management. Annals of Emergency Medicine, 59(3):165–175, 2012. Breathing room air beforehand, “desaturation will occur in the 45 to 60 seconds” of apnoea; finger oximeters may lag 30–60 s in sick patients. Accessed 2026-11-20.
  129. [129] David L. Woods, John M. Wyma, E. William Yund, Timothy J. Herron, and Bruce Reed. Factors influencing the latency of simple reaction time. Frontiers in Human Neuroscience, 9:131, 2015.
  130. [130] Haozhe Xie, Beichen Wen, Jiarui Zheng, Zhaoxi Chen, Fangzhou Hong, Haiwen Diao, and Ziwei Liu. DynamicVLA: A vision-language-action model for dynamic object manipulation. arXiv preprint arXiv:2601.22153, 2026.
  131. [131] Houlong Xiong, Zhenqi Qiu, Zechen Wang, Suohang Zhang, Yiyu Ren, Wanting Xu, Hongfei Niu, Chengyang He, Ge Sun, Ran Cheng, and Qian Zhu. REACT: Rolling denoising and dual decoupling for reactive robot control with VLA models. In Conference on Robot Learning, 2026.
  132. [132] Jenai Xuning Yang, Ashna Khetan, and Shun Zhang. Astranomy: An empirical study of GPT-6 astra as a native robot policy. Technical report, NVIDIA Research, 2026.
  133. [133] Yuanbo Yang. ORA: Open robot-use agents, 2026. Project report, October 2026.
  134. [134] Yaskawa Motoman. Clinical laboratory automation (AutoSorter 1200). Manufacturer application page, 2026. Accessed 2026-11-16.
  135. [135] Seonghyeon Ye, Yunhao Ge, Kaiyuan Zheng, et al. World action models are zero-shot policies. arXiv preprint arXiv:2602.15922, 2026.
  136. [136] Heng Yu, David D. Yuan, Juze Zhang, Changan Chen, Yao Feng, Michelle Baldonado, Steve Cousins, Li Fei-Fei, Jiajun Wu, and Ehsan Adeli. OpenWAM: An open framework for composable world-action models. arXiv preprint arXiv:2610.07922, 2026.
  137. [137] Jiarui Yuan, Yuxin Zuo, Xiaoyu Huang, Wenbo Zhang, Kwanyoung Park, et al. Democratizing robot-use agents: A unified harness with open models. arXiv preprint arXiv:2611.01560, 2026.
  138. [138] Z.ai. GLM-5.3. Open-weight language model (text input only), 2026.
  139. [139] Andy Zhai, Brae Liu, Bruno Fang, Chalse Cai, Ellie Ma, et al. Igniting VLMs toward the embodied space. arXiv preprint arXiv:2509.11766, 2025.
  140. [140] Yixian Zhang, Huanming Zhang, Feng Gao, Xiao Li, Zhihao Liu, et al. Harness VLA: Steering frozen VLAs into reliable manipulation primitives via memory-guided agents. arXiv preprint arXiv:2607.08448, 2026.
  141. [141] Jinliang Zheng, Jianxiong Li, Zhihao Wang, Dongxiu Liu, Xirui Kang, et al. X-VLA: Soft-prompted transformer as scalable cross-embodiment vision-language-action model. In International Conference on Learning Representations, 2026.
  142. [142] AED Plus Administrator’s Guide, Appendix A: Technical Specifications. ZOLL Medical Corporation, n.d. Manufacturer manual, reseller-hosted. Accessed 2026-11-16.

Appendix

Apps. A–C give the evaluation setup, the Tool-augmented EEF interface, and the task catalog; App. D the time limits; Apps. E–F further VLM analyses; Apps. G–K the task manifest, monitor checks, study map, logs, and release; and App. L a real-robot pilot.

Appendix A Simulation and Evaluation Details

Tab. 8 compares our settings with RoboDojo [18]; Tab. 9 gives task counts per domain.

Table 8: Simulation and sensor settings. Our rig, cameras, and rates follow RoboDojo [18]; rows marked † differ.
  • Simulator†
    Ours
    Isaac Sim 6.0.1, PhysX (CPU)
    RoboDojo
    Isaac Sim 5.1.0, Isaac Lab
  • Physics rate
    Ours
    250 Hz (\Delta t_{\mathrm{phys}}=4 ms)
    RoboDojo
    250 Hz (\Delta t=4 ms)
  • Control rate†
    Ours
    50 Hz (\Delta t_{\mathrm{ctrl}}=20 ms, 5 substeps)
    RoboDojo
    –
  • Policy / data rate
    Ours
    25 Hz nominal; Latency-Aligned at evaluation
    RoboDojo
    25 Hz
  • Rendering
    Ours
    once per policy observation
    RoboDojo
    every 10 physics steps
  • Renderer
    Ours
    RTX RaytracedLighting, DLAA, quality
    RoboDojo
    same
  • Robot
    Ours
    dual ARX X5, 6-DoF + parallel gripper
    RoboDojo
    same
  • Base separation
    Ours
    0.60 m, same height and yaw
    RoboDojo
    same
  • Rig placement†
    Ours
    per task (origin, yaw)
    RoboDojo
    one fixed world pose
  • Head camera pose
    Ours
    (0.04,0,0.543) m from base midpoint, 60^{\circ} down
    RoboDojo
    same
  • Head camera
    Ours
    Gemini 345Lg, 640\times 480, 96.0^{\circ}\times 79.6^{\circ}
    RoboDojo
    Gemini 345Lg, 640\times 480
  • Wrist cameras
    Ours
    D435 on link6, 640\times 480, 77.7^{\circ}\times 62.3^{\circ}
    RoboDojo
    same
  • Observation†
    Ours
    3\timesRGB (+depth), joints, EE poses, gripper, env. time, instruction
    RoboDojo
    3\timesRGB-D, joints, EE poses, gripper
  • Action
    Ours
    16-D absolute joint-position targets
    RoboDojo
    joint positions
  • Inference timing†
    Ours
    block-and-replay, L_{\mathrm{infer}}+\delta charged to env. time (\delta=20 ms)
    RoboDojo
    –
  • Episode horizon†
    Ours
    task time budget
    RoboDojo
    1.2\times P90 demo length
  • Episodes per task†
    Ours
    easy; 10 seeds per model
    RoboDojo
    50
  • Metrics†
    Ours
    PS / PSR / TSR / LTSR
    RoboDojo
    success rate, score
Table 9: Task suite by domain and primary temporal category. W: Temporal Window, R: Event-Reactive, T: Throughput.
  • Laboratory
    W
    6
    R
    7
    T
    3
    Tasks
    16
    Levels
    E / M / H
  • Household
    W
    4
    R
    3
    T
    3
    Tasks
    10
    Levels
    E / M / H
  • Healthcare
    W
    4
    R
    6
    T
    4
    Tasks
    14
    Levels
    E / M / H
  • Sports & games
    W
    2
    R
    5
    T
    3
    Tasks
    10
    Levels
    E / M / H
  • Industry
    W
    3
    R
    3
    T
    4
    Tasks
    10
    Levels
    E / M / H
  • Total
    W
    19
    R
    24
    T
    17
    Tasks
    60
Simulation and rig.

PhysX runs on the CPU at 250 Hz, five substeps per 20 ms control step, as in RoboDojo. Images are rendered once per policy observation with the RTX real-time renderer, which does not change the dynamics. The two arms stand side by side with bases 0.60 m apart; the head camera is 0.543 m above and 0.04 m in front of their midpoint, pitched 60^{\circ} down, and each wrist camera sits on the flange. Unlike RoboDojo, the rig is placed per task within each scene, and its geometry is checked at every reset. Every cue lies inside the head-camera image. Simulation and rendering run on RTX GPUs, with one episode per simulator process. The eight NVIDIA A100 80 GB GPUs serve model inference and policy fine-tuning.

Observations, actions, and episodes.

Proprioception comprises 16 joint positions, both EEF poses, and gripper widths. All methods output the same 16-D joint-position action through model-specific adapters. The main protocol uses the easy level with 10 seeds per task for every model, and the horizon is the task’s time budget.

Foundation-model settings.

VLMs and agent-framework backbones use provider-recommended settings with low thinking mode; all agent frameworks use Qwen3.8-27B. LTSR charges API-served models their measured API latency and locally served models their latency on the A100 node. DeepSeek V4.1 Flash and the text-only GLM-5.3 reference are accessed through APIs. Table 10 lists serving configurations for six open-weight models; their mean billed latencies range from 2.3 to 5.9 s per query.

Table 10: Inference configurations for LTSR on eight A100s. Each listed open-weight model uses its fastest speculative decoding: a built-in MTP head or a DFlash drafter. K: draft tokens per step (default of each model’s or drafter’s released serving configuration); speedup vs. no drafter; billed latency: mean per-query time charged to environment time. Qwen3.8-27B backs every agent framework; API-served models, including DeepSeek V4.1 Flash and GLM-5.3, are charged their measured API latency.
  • Qwen3.5-4B
    Decoding
    built-in MTP
    K
    3
    Accept. (%)
    70.0
    tok/s
    562.1
    Speedup
    2.20\times
    TTFT (s)
    0.22
    Billed latency (s)
    2.27
  • Qwen3.5-9B
    Decoding
    built-in MTP
    K
    3
    Accept. (%)
    72.1
    tok/s
    500.4
    Speedup
    1.82\times
    TTFT (s)
    0.23
    Billed latency (s)
    2.49
  • Gemma 4 26B-A4B
    Decoding
    z-lab DFlash
    K
    15
    Accept. (%)
    21.8
    tok/s
    289.5
    Speedup
    1.50\times
    TTFT (s)
    0.44
    Billed latency (s)
    4.28
  • Qwen3.8-27B
    Decoding
    DFlash2 drafter
    K
    7
    Accept. (%)
    42.6
    tok/s
    274.1
    Speedup
    2.44\times
    TTFT (s)
    0.32
    Billed latency (s)
    4.59
  • Muse Glimmer 30B
    Decoding
    Meta DFlash assistant
    K
    15
    Accept. (%)
    20.7
    tok/s
    259.8
    Speedup
    2.86\times
    TTFT (s)
    0.24
    Billed latency (s)
    4.72
  • Qwen3.8-Flash-Next
    Decoding
    built-in MTP
    K
    3
    Accept. (%)
    54.9
    tok/s
    212.0
    Speedup
    1.82\times
    TTFT (s)
    0.48
    Billed latency (s)
    5.94
Task validation.

The scripted oracle meets all clauses in 99.2% of episodes at the released limits. Human teleoperation achieves 96% TSR under the same temporal constraints.

A.1 Fine-tuning VLAs and WAMs

We hold out 15 tasks, one per category in each domain. The other 45 provide 610 oracle demonstrations (12–14 per task, easy and medium; 610,098 frames at 25 Hz) with head and wrist images, proprioception, environment time, and joint targets; evaluation seeds are disjoint from demonstration seeds. Elapsed environment time is appended to the instruction at 0.1 s resolution. All four policies start from their released RoboDojo checkpoints and are fine-tuned for three epochs on eight A100 GPUs with the defaults of their released training interfaces (Tab. 11); only the epoch count, the text limits, and normalization ranges that the demonstrations exceed are changed.

Table 11: Fine-tuning configuration (three epochs for every model). Except for the epoch count, text limits, and normalization ranges, all values are the defaults of each model’s released training interface. Batch: per-GPU batch \times gradient accumulation \times GPUs. Text limits in tokens; \pi_{0.5} includes discretized state tokens.
  • Initialization
    \pi_{0.5}
    RoboDojo sim
    X-VLA
    RoboDojo sim
    OpenWAM-\alpha
    RoboDojo sim
    InternW0-\Delta
    RoboDojo sim
  • Epochs
    \pi_{0.5}
    3
    X-VLA
    3
    OpenWAM-\alpha
    3
    InternW0-\Delta
    3
  • Action space
    \pi_{0.5}
    Joint delta, 14-D
    X-VLA
    EEF, 20-D (xyz, rot6d, gripper)
    OpenWAM-\alpha
    EEF, 20-D
    InternW0-\Delta
    Joint, 14-D
  • Action chunk
    \pi_{0.5}
    50 (2.0 s)
    X-VLA
    30 (1.2 s)
    OpenWAM-\alpha
    32 (1.28 s)
    InternW0-\Delta
    32 (1.28 s)
  • Camera input
    \pi_{0.5}
    Head + two wrists; 224^{2} each
    X-VLA
    Head only; 224^{2}
    OpenWAM-\alpha
    Three views tiled; 384\times 320
    InternW0-\Delta
    Three views tiled; 384\times 256
  • Text limit
    \pi_{0.5}
    200\to 288
    X-VLA
    50\to 224
    OpenWAM-\alpha
    512
    InternW0-\Delta
    128\to 256
  • Batch
    \pi_{0.5}
    32\times 1\times 8=256
    X-VLA
    32\times 1\times 8=256
    OpenWAM-\alpha
    4\times 1\times 8=32
    InternW0-\Delta
    8\times 32\times 8=2048
  • Learning rate
    \pi_{0.5}
    2.5\times 10^{-5}; 500-step warm-up; cosine to 2.5\times 10^{-6}
    X-VLA
    10^{-4}, constant; VLM multiplier 0.1; first 1K steps update only soft prompts and action heads
    OpenWAM-\alpha
    10^{-4}; 5% warm-up; cosine to 10^{-6}
    InternW0-\Delta
    5\times 10^{-5}; 5% warm-up; cosine to 5\times 10^{-7}
  • Optimizer
    \pi_{0.5}
    AdamW (0.9,0.95); EMA 0.99; FSDP
    X-VLA
    AdamW (0.9,0.95)
    OpenWAM-\alpha
    AdamW (0.9,0.95); weight decay 0.01; bf16; ZeRO-2
    InternW0-\Delta
    AdamW (0.9,0.95); weight decay 0.01; bf16; ZeRO-1
  • Normalization
    \pi_{0.5}
    Quantile; state range expanded
    X-VLA
    None; fixed loss weights
    OpenWAM-\alpha
    Min–max; EEF position range expanded
    InternW0-\Delta
    Z-score; joint-1 std expanded

Appendix B Tool-augmented EEF Interface

Every VLM in Tab. 5 uses the same eleven tools, settings, and prompt on all 60 tasks.

Observations and tools.

For vision-capable agents, each turn carries the head and wrist images, the instruction, the task clock, and each arm’s measured tool point and gripper opening. The text-only GLM-5.3 reference receives no images. Head depth only lifts a chosen pixel to a world point; the agent never reads object poses, task state, or event times, and tool results are measurements only. The model answers with one to four tool calls (Tab. 12). A target is a head-image pixel or a world point, and a when trigger holds a motion until the image patch at a pixel changes. Invalid calls are refused with the valid range.

Table 12: The eleven tools in Tool-augmented EEF. Numeric arguments are model-chosen within fixed ranges; targets are pixels or world points.
  • move
    Behavior
    Straight-line move of the tool point to a target raised by height.
    Arguments
    arm, to, height, approach, yaw, tilt, gripper, opening, speed, when
  • move_by
    Behavior
    Straight-line move by an offset from the measured tool point; with guard it stops on contact and keeps pressing.
    Arguments
    arm, by, guard, gripper, opening, speed, when
  • home
    Behavior
    Return to the arm’s initial pose.
    Arguments
    arm, gripper, opening, speed, when
  • grasp
    Behavior
    Open, approach from the stand-off, go depth past the target under guard, close with squeeze, lift.
    Arguments
    arm, object, approach, yaw, tilt, depth, opening, squeeze, lift, when
  • place
    Behavior
    Rise to the carry clearance, move over the release point, lower (guarded for on/into), open, back off.
    Arguments
    arm, target, mode, height, yaw, opening, when
  • press
    Behavior
    Closed fingers from the press stand-off, depth past the point, hold, back off.
    Arguments
    arm, target, approach, yaw, tilt, depth, hold, when
  • push
    Behavior
    Closed fingers come down behind the point and slide by an offset.
    Arguments
    arm, by, target, approach, yaw, tilt, when
  • pull
    Behavior
    Close on the point as in grasp, drag by an offset, release.
    Arguments
    arm, by, target, approach, yaw, tilt, depth, opening, squeeze, when
  • turn
    Behavior
    Close on the point and rotate the hand by angle; with hinge, swing on an arc about a world axis (lever, crank, door).
    Arguments
    arm, angle, target, hinge, approach, yaw, tilt, depth, opening, squeeze, when
  • wait
    Behavior
    Hold both arms for a duration, until a clock time, or until a watched pixel changes.
    Arguments
    seconds, until_t, watch, timeout
  • configure
    Behavior
    Change episode settings (speeds, stand-offs, contact and arrival thresholds, watch parameters); returns all of them.
    Arguments
    the 19 settings
Execution.

Tools execute by inverse kinematics as 16-D joint targets, in closed loop on proprioception and at the rig’s joint speeds. Guarded motions stop on contact, and unreachable or colliding motions fail without moving. The interface thus adds no privileged information and no per-task tuning, and every query is charged its latency (Sec. 3.1).

Other interfaces in Tab. 4.

Agent-as-Policy [103] emits low-level arm commands at every query; RoboDojo EEF [18] sets absolute tool poses, planned with CuRobo.

Appendix C Task Catalog and Demonstrations

Table 13: Task catalog: Laboratory and Healthcare. IDs are domain-local. A: Temporal Window; B: Event-Reactive; C: Throughput.
  • Laboratory (16 tasks: 6 A, 7 B, 3 C)
  • A1
    Task
    Water collection
    Cat.
    A
    Physical goal and temporal obligation
    Close the faucet while the collected volume is within the target band.
  • A2
    Task
    Phase separation
    Cat.
    A
    Physical goal and temporal obligation
    Close the stopcock at the phase boundary before the upper phase enters the receiver.
  • A3
    Task
    Chromatography fractions
    Cat.
    A
    Physical goal and temporal obligation
    Exchange receiving tubes to collect each colored fraction during its elution interval.
  • A4
    Task
    Titration endpoint
    Cat.
    A
    Physical goal and temporal obligation
    Reduce or stop titrant flow at the indicator endpoint, before excess titrant is added.
  • A5
    Task
    Film development
    Cat.
    A
    Physical goal and temporal obligation
    Retain the reel in the stop bath for the specified interval, then transfer it to the fixer.
  • A6
    Task
    Warm-to-ice transfer
    Cat.
    A
    Physical goal and temporal obligation
    Pick the tube up from the bench stand, keep it in the warm bath for the specified duration, then transfer it to ice.
  • B1
    Task
    Hotplate isolation
    Cat.
    B
    Physical goal and temporal obligation
    After the alarm, lift the beaker clear of the hotplate and place it upright in the safety tray.
  • B2
    Task
    Electrical isolation
    Cat.
    B
    Physical goal and temporal obligation
    Open the knife switch after the load indicator turns red, before the response deadline.
  • B3
    Task
    Motor-stall response
    Cat.
    B
    Physical goal and temporal obligation
    Detect the stopped wheel and disconnect its supply before the response deadline.
  • B4
    Task
    Test-tube rescue
    Cat.
    B
    Physical goal and temporal obligation
    Grasp and stabilize the tilting tube after the trigger, before it falls or loses sample.
  • B5
    Task
    Freezer-door closure
    Cat.
    B
    Physical goal and temporal obligation
    Close the released freezer door after its alarm and before the response deadline.
  • B6
    Task
    Vacuum relief
    Cat.
    B
    Physical goal and temporal obligation
    Press the vent plunger after the pressure warning, before the bumping deadline.
  • B7
    Task
    Waste-inlet closure
    Cat.
    B
    Physical goal and temporal obligation
    Close the inlet pinch clamp after the level alarm, before the carboy overflows.
  • C1
    Task
    Rack organization
    Cat.
    C
    Physical goal and temporal obligation
    Sort upright tubes into color-matched racks within the horizon and accuracy requirement.
  • C2
    Task
    Rack loading
    Cat.
    C
    Physical goal and temporal obligation
    Load upright samples into color-matched slots while meeting the rate and accuracy targets.
  • C3
    Task
    Calibration placement
    Cat.
    C
    Physical goal and temporal obligation
    Align samples with their color markers and axes while meeting the rate and accuracy targets.
  • Healthcare (14 tasks: 4 A, 6 B, 4 C)
  • A1
    Task
    Drip-chamber level
    Cat.
    A
    Physical goal and temporal obligation
    Open the roller clamp so that the bag drips into the chamber, then close it while the chamber level is inside the target band.
  • A2
    Task
    Sequential bag switch
    Cat.
    A
    Physical goal and temporal obligation
    Switch the selector after the first bag runs empty but before its drip chamber runs dry.
  • A3
    Task
    Bag-valve ventilation
    Cat.
    A
    Physical goal and temporal obligation
    Squeeze the resuscitator bag once per 6 s breath cycle, each breath inside the window around its beat, with no extra breaths.
  • A4
    Task
    Infusion startup
    Cat.
    A
    Physical goal and temporal obligation
    After the request, seat the bag on the trainer spike and hook, then press the pump START key before the deadline.
  • B1
    Task
    Oxygen desaturation
    Cat.
    B
    Physical goal and temporal obligation
    After the low-SpO2 alarm, turn the wall flowmeter until its float settles in the ordered flow band.
  • B2
    Task
    AED response
    Cat.
    B
    Physical goal and temporal obligation
    After the alarm, place both trainer pads and trigger the simulated shock before its deadline.
  • B3
    Task
    Hazardous-drug spill
    Cat.
    B
    Physical goal and temporal obligation
    After the drug bottle breaks, cover the spreading spill with the absorbent towel, then put both glass pieces in the sharps bin.
  • B4
    Task
    Ventilator reconnection
    Cat.
    B
    Physical goal and temporal obligation
    After the circuit comes off the tracheostomy tube, reseat the elbow on the connector and release it.
  • B5
    Task
    Anaphylaxis auto-injector
    Cat.
    B
    Physical goal and temporal obligation
    After the low-blood-pressure alarm, press the adrenaline auto-injector’s tip on the thigh pad until it fires and hold it for 3 s, before the response deadline.
  • B6
    Task
    Haemorrhage tourniquet
    Cat.
    B
    Physical goal and temporal obligation
    After the thigh wound starts to bleed, turn the tourniquet’s windlass rod half a turn into its retaining clip and release it before the response deadline.
  • C1
    Task
    Pharmacy order bins
    Cat.
    C
    Physical goal and temporal obligation
    Fill prescription bins with the requested vials while meeting the rate and accuracy targets.
  • C2
    Task
    Instrument-tray sorting
    Cat.
    C
    Physical goal and temporal obligation
    Place instruments flat in their matching tray slots within the shift and accuracy limits.
  • C3
    Task
    Crash-cart restocking
    Cat.
    C
    Physical goal and temporal obligation
    Restock upright vials in the matching drawer lanes within the shift and accuracy limits.
  • C4
    Task
    Blood-tube triage
    Cat.
    C
    Physical goal and temporal obligation
    Route upright tubes to the analyzer racks matching their stopper colors within the shift.

Tab. 13 lists all 60 tasks; A, B, and C denote Temporal Window, Event-Reactive, and Throughput (W, R, T in Tab. 9), and levels and seeds instantiate them without adding tasks. Fig. 11 shows scenes and asset sources, and Figs. 8–10 show oracle demonstrations at the medium level (seed 50); frame labels are environment times.

Windows that open at a known start.

In four Temporal Window tasks the interval opens at the start or at a rule-defined cue, so in practice only its end binds. Healthcare A4 (from the instruction) and Household A4 (from the episode start) set a stated time limit on a multi-step procedure. Sports & games A1 and A2 follow game clocks: the move and clock press are due after the opponent’s press, and the shot must be released between READY and the shot-clock expiry, so a release before READY fails. We class them as Temporal Window because the interval is fixed in advance by the instruction or the rules and the robot paces a procedure inside it, instead of responding to a fault or hazard. Their limits also satisfy the Event-Reactive inequality, so they can equally be read as deadline tasks; all category results count them under A.

Secondary constraints.

Besides its primary requirement, a task may carry further timed clauses, listed per task in Tabs. 17–22. For example, Laboratory A5 must also release the reel in the fixer within 5 s of the lift, and Healthcare B3 must cover the spill within 0.4 of its response limit. Temporal success requires every clause.

C.1 Example Demonstrations

We describe one oracle run per category (Sec. 4.2), in environment time.

Temporal Window: Film development (Laboratory A5, Fig. 8b).

The reel must stay in the stop bath for 12 s from its measured immersion, be lifted at most 4, 2, or 1 s later (easy, medium, hard), and rest released in the fixer within 5 s of the lift. The oracle times the lift from the measured immersion; its rise lands 0.05 s after the countdown ends.

Event-Reactive: Motor-fault emergency stop (Industry B2, Fig. 9a).

At a seeded onset (14–18 s) the fault panel switches from RUN to MOTOR FAULT; the robot must actuate the emergency stop within 3 s at the easy level, and a press before the onset fails. The oracle holds its start pose until the onset and actuates the stop about 2.0 s after it.

Throughput: Ball service (Sports & games C3, Fig. 10b).

Six ball demands follow a schedule (the first at 21.65, 13.20, or 8.05 s, then every 12.00, 7.32, or 4.46 s); a demand that finds no stocked ball is served late by the next ball stocked, and more than four balls in the hopper fail as overflow. The oracle runs one grasp-and-place cycle per arm to keep the station stocked ahead of each demand.

Table 14: Task catalog (continued): Household, Sports & games, and Industry. Parenthesized Industry numbers are recording aliases.
  • Household (10 tasks: 4 A, 3 B, 3 C)
  • A1
    Task
    Sugar pouring and stirring
    Cat.
    A
    Physical goal and temporal obligation
    Tilt the open jar to pour sugar into the tea, set it down while the sugar heap is within the gram band, then stir and return the spoon.
  • A2
    Task
    Ice dispensing
    Cat.
    A
    Physical goal and temporal obligation
    Hold the glass under the dispenser and release the paddle when the ice reaches the target band.
  • A3
    Task
    Pancake flip
    Cat.
    A
    Physical goal and temporal obligation
    Flip the pancake when its underside is golden, then leave it cooking in the pan.
  • A4
    Task
    Kettle pouring
    Cat.
    A
    Physical goal and temporal obligation
    Pour the target mass of water into the jug and set the kettle down before the deadline.
  • B1
    Task
    Faucet shutoff
    Cat.
    B
    Physical goal and temporal obligation
    Stop the running faucet before the filling bowl overflows.
  • B2
    Task
    Rolling-object catch
    Cat.
    B
    Physical goal and temporal obligation
    Catch and retain the rolling object before it falls from the counter.
  • B3
    Task
    Burner shutoff
    Cat.
    B
    Physical goal and temporal obligation
    Turn off the burner after the pot catches fire.
  • C1
    Task
    Meal service
    Cat.
    C
    Physical goal and temporal obligation
    Serve the ordered meals in order, relaying bowls via the staging mat to the single serving position before each waiter pickup.
  • C2
    Task
    Cola service
    Cat.
    C
    Physical goal and temporal obligation
    Fill the glasses to their marked levels without spilling, then return both bottles upright.
  • C3
    Task
    Cutlery organization
    Cat.
    C
    Physical goal and temporal obligation
    Sort the mixed utensils into the matching drawer compartments as quickly as possible.
  • Sports & games (10 tasks: 2 A, 5 B, 3 C)
  • A1
    Task
    Chess exchange and clock
    Cat.
    A
    Physical goal and temporal obligation
    After the opponent presses the clock, execute the scheduled move and press the clock in time.
  • A2
    Task
    Basketball shot clock
    Cat.
    A
    Physical goal and temporal obligation
    Release a shot after READY and before the shot clock expires.
  • B1
    Task
    Whack-a-mole
    Cat.
    B
    Physical goal and temporal obligation
    Hit green moles with held mallets before they retract; avoid red decoys.
  • B2
    Task
    Reactive boxing
    Cat.
    B
    Physical goal and temporal obligation
    Strike the indicated pad after GO, then return to guard within the response limits.
  • B3
    Task
    Bench-press assistance
    Cat.
    B
    Physical goal and temporal obligation
    After the lifter stalls, catch the falling bar with both hands and return it to the rack.
  • B4
    Task
    Red-light freeze
    Cat.
    B
    Physical goal and temporal obligation
    Push on green; stop hands and tools after red and remain still until green returns.
  • B5
    Task
    Two-stick taiko
    Cat.
    B
    Physical goal and temporal obligation
    Strike each cued drum within its note window; paired notes require simultaneous hits.
  • C1
    Task
    Pool-ball racking
    Cat.
    C
    Physical goal and temporal obligation
    Place the required balls into the rack as quickly as possible, with stable released placements.
  • C2
    Task
    Speed cups
    Cat.
    C
    Physical goal and temporal obligation
    Build each displayed cup pattern, release stable cups and press the bell to advance.
  • C3
    Task
    Ball-machine service
    Cat.
    C
    Physical goal and temporal obligation
    Replenish the feeder for scheduled demand without exceeding hopper capacity.
  • Industry (10 tasks: 3 A, 3 B, 4 C)
  • A1
    Task
    Zincate dip and rinse
    Cat.
    A
    Physical goal and temporal obligation
    Pick the part from the loading pad and immerse it in the zincate bath; lift it out within the recipe window after full immersion, then release it in the rinse bath.
  • A2
    Task
    Rotary-carrier loading
    Cat.
    A
    Physical goal and temporal obligation
    Release the pump housing upright in the designated carrier while it crosses the loading sector.
  • A3
    Task
    Adhesive cover seating
    Cat.
    A
    Physical goal and temporal obligation
    Seat the housing cover within the allowed interval after adhesive application.
  • B1
    Task
    Leak isolation
    Cat.
    B
    Physical goal and temporal obligation
    Fully close the isolation valve within the response limit after the pipe starts leaking.
  • B2
    Task
    Motor emergency stop
    Cat.
    B
    Physical goal and temporal obligation
    Press the stop button within the response limit after the motor-test warning.
  • B3
    Task
    Bearing arrest and recovery
    Cat.
    B
    Physical goal and temporal obligation
    Stop the rolling bearing inside the safety area after zone entry, then recover it to the tray.
  • C1
    Task
    Maintenance-kit packing
    Cat.
    C
    Physical goal and temporal obligation
    Pack a bearing, bracket and pin into each case, release all items and move completed kits to output.
  • C2
    Task
    Carton shelving
    Cat.
    C
    Physical goal and temporal obligation
    Match carton SKUs to shelf identities, release cartons upright and withdraw before counting them.
  • C3
    Task
    Weigh-and-sort
    Cat.
    C
    Physical goal and temporal obligation
    Weigh each part on the bench scale, released and at rest, then sort it by the settled reading into a PASS or REJECT (underweight) tray.
  • C4
    Task
    Eyeshadow assembly
    Cat.
    C
    Physical goal and temporal obligation
    Place the four colors in their designated case positions, then move the completed palette to output.
  • Total: 60 tasks; 19 A, 24 B and 17 C.
Figure 8: Category A: Temporal Window. (a) Wait until the underside is golden, then flip the pancake. (b) Immerse the reel in the stop bath, lift it once the 12 s countdown ends, and release it in the fixer.
Figure 9: Category B: Event-Reactive. (a) The fault panel turns from RUN to MOTOR FAULT, and the robot actuates the emergency stop. (b) The LOW BP alarm triggers the auto-injector: grasp it, press its tip on the thigh pad, and hold for 3 s.
Figure 10: Category C: Throughput. (a) Repeated placements fill the sample racks. (b) Repeated feeder loading serves successive ball demands.
Figure 11: Scenes and assets across the five domains, two task scenes per column. Excluding robots, room shells, variants, and procedural props, the domains use 27 (Household), 14 (Laboratory), 26 (Healthcare), 23 (Industry), and 21 (Sports & games) object and fixture models, from Lightwheel Kitchen, RoboCasa, YCB-Video, HANDAL, IndustReal, Sketchfab, Poly Haven, HOT3D, CAD libraries, and NVIDIA Isaac.

Appendix D Time Limits: Sources and Calibration

Each level’s time is set either by a physical parameter of the scene or by a time limit (Tabs. 15 and 16); Tabs. 17–22 give the source of every value.

Windows set by a physical parameter (18 tasks, Tab. 15).

Here the window follows from a quantity in the scene (a flow rate, a band, a slope, a rotating sector, or the tolerance around a prescribed duration), taken from a real-world document where one exists. Medium and hard change the quantity itself, and no window is shorter than 1 s.

Table 15: Process-set windows: the quantity each level changes and the resulting time. E/M/H: easy/medium/hard. Lab.: Laboratory; Hlth.: Healthcare; House.: Household; Ind.: Industry.
  • Lab. A1
    Quantity changed by the level
    Accepted volume band below the 500 mL mark, at a fixed 10 mL/s
    E / M / H
    440 / 460 / 480–500 mL
    Resulting time (E / M / H)
    6 / 4 / 2 s to close the faucet
  • Lab. A2
    Quantity changed by the level
    Lower phase that may remain when the stopcock closes, at 5 mL/s
    E / M / H
    20 / 12.5 / 7.5 mL
    Resulting time (E / M / H)
    4 / 2.5 / 1.5 s
  • Lab. A3
    Quantity changed by the level
    Gap between two eluting bands
    E / M / H
    20 / 12 / 5 s
    Resulting time (E / M / H)
    the same, to exchange the tube
  • Lab. A4
    Quantity changed by the level
    Titrant flow with the stopcock open (2 mL endpoint band)
    E / M / H
    0.33 / 0.50 / 1.0 mL/s
    Resulting time (E / M / H)
    6 / 4 / 2 s
  • Lab. A5
    Quantity changed by the level
    Lateness allowed after the 12 s stop bath
    E / M / H
    +4 / 2 / 1 s
    Resulting time (E / M / H)
    the same
  • Lab. A6
    Quantity changed by the level
    Tolerance on the 30 s warm bath
    E / M / H
    \pm4 / 2 / 1 s
    Resulting time (E / M / H)
    the same
  • Hlth. A1
    Quantity changed by the level
    Time the chamber level stays in the 40–55 % band
    E / M / H
    6 / 4.5 / 3 s
    Resulting time (E / M / H)
    the same
  • Hlth. A2
    Quantity changed by the level
    Time from bag 1 empty until its drip chamber runs dry
    E / M / H
    8 / 5.5 / 3 s
    Resulting time (E / M / H)
    the same
  • Hlth. A3
    Quantity changed by the level
    Window around each breath, one every 6 s
    E / M / H
    3 / 2 / 1 s
    Resulting time (E / M / H)
    the same
  • House. A1
    Quantity changed by the level
    Accepted sugar mass in the glass
    E / M / H
    10–30 / 10–25 / 10–15 g
    Resulting time (E / M / H)
    at least 1.09 s at hard at the fastest pour
  • House. A2
    Quantity changed by the level
    Interval between ice cubes while the paddle is held
    E / M / H
    2.0 / 1.5 / 1.3 s
    Resulting time (E / M / H)
    release window of at least 1 s
  • House. A3
    Quantity changed by the level
    Pan heat: browning rate relative to easy, which follows a recipe (first side about 2 min)
    E / M / H
    \times1 / 1.33 / 2
    Resulting time (E / M / H)
    first side golden after 69–120 / 52–90 / 35–60 s
  • House. B1
    Quantity changed by the level
    Faucet flow
    E / M / H
    4.5 / 6.0 / 8.3 L/min
    Resulting time (E / M / H)
    overflow after 10.7–18.7 / 8–14 / 5.8–10.1 s
  • House. B2
    Quantity changed by the level
    Slope of the board the object rolls down
    E / M / H
    4.5 / 6 / 9∘
    Resulting time (E / M / H)
    1.2–2.3 s to the counter edge (about 1.2 s at hard)
  • House. B3
    Quantity changed by the level
    Growth rate of the pan fire
    E / M / H
    \times0.75 / 1 / 1.5
    Resulting time (E / M / H)
    flame spreads after 48–90 / 36–68 / 24–45 s
  • Ind. A2
    Quantity changed by the level
    Loading sector of the table turning at 5∘/s
    E / M / H
    60 / 50 / 40∘
    Resulting time (E / M / H)
    12 / 10 / 8 s
  • Sports B4
    Quantity changed by the level
    Time allowed to come to rest in each red phase
    E / M / H
    8 / 4 / 2 s
    Resulting time (E / M / H)
    the same
  • Sports B5
    Quantity changed by the level
    Window around each drum note, notes 5 s apart
    E / M / H
    \pm2 / 1.41 / 1 s
    Resulting time (E / M / H)
    the same
Time limits (42 tasks, Tab. 16).

In the other tasks the requirement is a deadline, a budget, or a throughput tier, set against t, the slowest of ten oracle runs (seeds 0–9). Hard is \max(1.25t,\ t+0.30\,\text{s},\ 1\,\text{s}), so a policy as fast as the oracle keeps a fifth of the limit to perceive and decide. Easy is a documented real-world time where one exists (e.g., a ventilator’s 20 s apnea interval or the 14 s shot clock) and 4t otherwise; medium is the geometric mean. Throughput tiers use 4, \sqrt{5}, and 1.25\times t_{o} by default; Sports C3 uses the process-capped schedule in Tab. 22.

Table 16: Time limits. t: slowest reference time over seeds 0–9. Easy basis: doc, a documented real-world time; 4t where none exists; cap, the time the scene’s process allows where 4t would exceed it. Hard is \max(1.25t,\ t+0.30\,\text{s},\ 1\,\text{s}) and medium is \sqrt{\text{easy}\times\text{hard}}. The 17 Throughput tasks use 4/\sqrt{5}/1.25\times t_{o} by default, with the process-capped exception of Sports C3 (Tabs. 17–22). Abbreviations as in Tab. 15.
  • Lab. B1
    Limit
    Alarm to beaker lifted
    t (s)
    1.17
    Easy basis
    4t
    E / M / H (s)
    4.69 / 2.63 / 1.48
  • Lab. B1
    Limit
    Alarm to beaker placed in the tray
    t (s)
    5.08
    Easy basis
    4t
    E / M / H (s)
    20.32 / 11.36 / 6.35
  • Lab. B2
    Limit
    Red indicator to knife switch open
    t (s)
    1.50
    Easy basis
    4t
    E / M / H (s)
    6.02 / 3.36 / 1.88
  • Lab. B3
    Limit
    Motor stall to power cut
    t (s)
    1.59
    Easy basis
    4t
    E / M / H (s)
    6.37 / 3.56 / 1.99
  • Lab. B4
    Limit
    Tube tilt to tube caught
    t (s)
    1.69
    Easy basis
    4t
    E / M / H (s)
    6.76 / 3.79 / 2.12
  • Lab. B5
    Limit
    Door alarm to freezer door closed
    t (s)
    1.82
    Easy basis
    4t
    E / M / H (s)
    7.28 / 4.07 / 2.28
  • Lab. B6, B7
    Limit
    Warning to plunger pressed; alarm to inlet clamped
    t (s)
    0.32
    Easy basis
    4t
    E / M / H (s)
    1.3 / 1.14 / 1.0
  • Hlth. A4
    Limit
    Instruction to pump START pressed
    t (s)
    6.66
    Easy basis
    4t
    E / M / H (s)
    26.64 / 14.9 / 8.33
  • Hlth. B1
    Limit
    Alarm to oxygen float settled in the band
    t (s)
    4.15
    Easy basis
    doc: nurses’ median time to reach an alarm
    E / M / H (s)
    55 / 16.9 / 5.19
  • Hlth. B2
    Limit
    Arrest to shock (low end of a seeded range)
    t (s)
    23.13
    Easy basis
    4t
    E / M / H (s)
    92.52 / 51.73 / 28.92
  • Hlth. B3
    Limit
    Break to both glass pieces binned (low end)
    t (s)
    14.61
    Easy basis
    4t
    E / M / H (s)
    58.44 / 32.68 / 18.27
  • Hlth. B4
    Limit
    Disconnection to circuit reseated
    t (s)
    3.14
    Easy basis
    doc: ventilator apnea interval
    E / M / H (s)
    20 / 8.87 / 3.93
  • Hlth. B5
    Limit
    Alarm to end of the 3 s injector hold
    t (s)
    6.90
    Easy basis
    doc: untrained adults’ mean time
    E / M / H (s)
    33.7 / 17.05 / 8.63
  • Hlth. B6
    Limit
    Bleeding onset to windlass secured
    t (s)
    4.35
    Easy basis
    doc: trained providers’ time
    E / M / H (s)
    24 / 11.43 / 5.44
  • House. A4
    Limit
    Start to kettle set down
    t (s)
    28.69
    Easy basis
    4t
    E / M / H (s)
    115 / 64 / 36
  • Ind. A1
    Limit
    Width of the exit window after the minimum dip
    t (s)
    8.11
    Easy basis
    doc: 50 s longest first dip
    E / M / H (s)
    28 / 16.85 / 10.14
  • Ind. A3
    Limit
    Bead end to cover seated
    t (s)
    13.17
    Easy basis
    doc: 40 s open time
    E / M / H (s)
    40 / 25.67 / 16.47
  • Ind. B1
    Limit
    Leak onset to valve closed
    t (s)
    5.02
    Easy basis
    cap: spill tray full
    E / M / H (s)
    14 / 9.38 / 6.28
  • Ind. B2
    Limit
    Warning to stop button actuated
    t (s)
    2.02
    Easy basis
    3 s, 3.3\times the slowest measured press
    E / M / H (s)
    3 / 2.75 / 2.53
  • Ind. B3
    Limit
    Zone entry to stable arrest
    t (s)
    1.19
    Easy basis
    4t
    E / M / H (s)
    4.77 / 2.67 / 1.50
  • Sports A1
    Limit
    Opponent’s press to own clock press
    t (s)
    7.90
    Easy basis
    doc: 30 s increment
    E / M / H (s)
    30 / 17 / 10
  • Sports A2
    Limit
    READY to shot released
    t (s)
    4.59
    Easy basis
    doc: 14 s shot clock
    E / M / H (s)
    14 / 9 / 6
  • Sports B1
    Limit
    Mole rise to hit
    t (s)
    1.76
    Easy basis
    cap: 4 s between moles
    E / M / H (s)
    4.0 / 3.0 / 2.2
  • Sports B2
    Limit
    GO cue to pad hit; hit to guard
    t (s)
    0.68; 0.72
    Easy basis
    cap: next cue
    E / M / H (s)
    1.6 / 1.25 / 1.0; 1.4 / 1.2 / 1.05
  • Sports B3
    Limit
    Bar descent to catch
    t (s)
    0.51
    Easy basis
    4t
    E / M / H (s)
    2.05 / 1.43 / 1.0
Table 17: Time-parameter provenance: Laboratory. (a) Tasks whose window is set by a physical parameter of the scene (Tab. 15); their values are not sourced. (b) Tasks with a time limit (Tab. 16) and Throughput tasks; each value is compared with a documented real-world time.
  • A1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Faucet flow, handle fully open
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    10 mL/s at every tier
    (a) Window set by a physical parameter (Tab. 15) Note
    500 mL fill in 50 s; design setting for a low-flow metering outlet.
  • A1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Accepted band below the 500 mL mark
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    440/460/480–500 mL
    (a) Window set by a physical parameter (Tab. 15) Note
    6/4/2 s of flow before the mark. Oracle margin (hard): 1.04 s early side, 0.96 s late side.
  • A2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Drain rate; lower phase
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    5 mL/s; 120 mL
    (a) Window set by a physical parameter (Tab. 15) Note
    One constant-flow pass; the interface reaches the stopcock 24 s after opening.
  • A2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Lower phase that may remain when the stopcock closes
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    20/12.5/7.5 mL
    (a) Window set by a physical parameter (Tab. 15) Note
    4/2.5/1.5 s of drainage before contamination. Oracle closes 0.76 s before contamination.
  • A3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Eluent flow
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    1.5 mL/s (90 mL/min)
    (a) Window set by a physical parameter (Tab. 15) Note
    Flash-chromatography solvent descent in a 47 mm column (88 mL/min).
  • A3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Band volume
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    13.5 mL per band
    (a) Window set by a physical parameter (Tab. 15) Note
    9 s per band at the eluent flow; a run lasts 63–108 s.
  • A3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Gap between bands (tube switch)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    20/12/5 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Time to exchange the tube between two bands; the oracle needs about 1.9 s per switch.
  • A4
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Titrant flow, stopcock open
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    0.33/0.50/1.0 mL/s
    (a) Window set by a physical parameter (Tab. 15) Note
    6/4/2 s to pass the 2 mL endpoint band.
  • A4
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Endpoint band (first pink to excess)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    18–20 mL
    (a) Window set by a physical parameter (Tab. 15) Note
    6/4/2 s at the tier’s full flow. Oracle hard leaves 0.46 mL.
  • A5
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Stop-bath time before the fixer
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    12 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Prescribed bath time; the lateness tolerance below runs from its end.
  • A5
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Lift lateness tolerance (late side only)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    +4/2/1 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Hard is the 1 s floor. Oracle lateness 0.052 s.
  • A5, A6
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Loading limit (A5: reel into the stop bath; A6: tube picked from the bench stand)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    15 s (untiered)
    (a) Window set by a physical parameter (Tab. 15) Note
    Design setting; oracle immersed after 4.08 s.
  • A5
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Release in the fixer after the lift
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    5 s (untiered)
    (a) Window set by a physical parameter (Tab. 15) Note
    Design setting; oracle releases at most 2.40 s after the lift.
  • A6
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Warm-bath (heat-shock) duration
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    30 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Prescribed bath time; the exit tolerance below is centred on it.
  • A6
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Bath-exit tolerance
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    \pm4/2/1 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Hard is the 1 s floor. Oracle error 0.000 s at every tier.
  • A6
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Transfer to ice after bath exit
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    5 s (untiered)
    (a) Window set by a physical parameter (Tab. 15) Note
    Design setting; oracle 3.14 s.
  • (b) Time limit or throughput tier (Tab. 16)
  • Task
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Parameter
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15) Note
    Source and relation to our value
  • B1–B7
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Event onset after the episode start
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    4–10 s, uniform (all tiers)
    (a) Window set by a physical parameter (Tab. 15) Note
    Constant foreperiods let subjects predict the onset, randomly intermixed ones do not [25, 38]; we draw it per seed.
  • B1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Lift deadline after the alarm
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    4.69/2.63/1.48 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=1.17 s; easy 4t. Drivers’ perception–brake time is 1.25 s for unexpected and 1.5 s for surprise events [48]; hard is 0.99\times, easy 3.1\times the surprise time.
  • B1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Placement deadline in the tray
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    20.32/11.36/6.35 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=5.08 s; easy 4t. Analogy only: surprise reaction 1.5 s [48], fast 30 cm reach-to-grasp 0.42 s [107], block transfer 0.78 s [78]: 2.7 s; hard is 2.4\times that.
  • B2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Knife-switch isolation deadline
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    6.02/3.36/1.88 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=1.50 s (easy 4t), incl. 0.6 s oracle cue delay. Subjects stopped an unexpected robot motion by releasing a held button in 0.53 s on average, 1.42 s at mean{}+2 SD [52]; hard is 1.3\times the latter.
  • B3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Power cut after motor stall
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    6.37/3.56/1.99 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=1.59 s; easy 4t. Hard is 1.4\times the 1.42 s (mean{}+2 SD) robot-stop response [52], within the “order of seconds” to stall damage of small DC motors [96].
  • B4
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Catch the tube after 32∘ tilt
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    6.76/3.79/2.12 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=1.69 s with the rig centred on the tube; easy 4t. Simple visual reaction (0.21–0.23 s [129]) plus a fast 30 cm reach-to-grasp (0.42 s [107]) is 0.63–0.65 s; hard is 3.3\times that.
  • B5
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Freezer-door closing deadline
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    7.28/4.07/2.28 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=1.82 s with the freezer facing the rig, incl. 0.3 s cue delay; easy 4t. Shortest documented opening 10–15 s [120]: ours 1.4–6.6\times shorter; real door alarms wait (default 2 min [93]).
  • B6
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Vent-plunger deadline
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    1.3/1.14/1.0 s
    (a) Window set by a physical parameter (Tab. 15) Note
    t=0.32 s; easy 4t; hard is the 1 s floor. Simple visual reaction (0.21–0.23 s [129]) plus a fast reach (0.42 s [107]) is 0.63–0.65 s; ours is 1.5–2.1\times that.
  • B7
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Inlet-clamp deadline
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    1.3/1.14/1.0 s
    (a) Window set by a physical parameter (Tab. 15) Note
    As B6 (human reaction plus reach 0.63–0.65 s [129, 107]; ours 1.5–2.1\times). Inflow is 10 mL of headroom divided by the deadline.
  • C1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Time per tube, N=20–30 tubes
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    15.908/8.893/4.971 s per item, \times N total
    (a) Window set by a physical parameter (Tab. 15) Note
    t_{o}=3.977 s/tube. Hard = 724 tubes/h; commercial sorters do 1,150–1,200/h [134, 111], 1.6–1.7\times faster.
  • C2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Time per sample, N=20–30
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    11.228/6.277/3.509 s per item, \times N total
    (a) Window set by a physical parameter (Tab. 15) Note
    t_{o}=2.807 s/item. Hard = 1,026/h, 86–89 % of the sorter rates [134, 111] (different machine).
  • C3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Time per sample, N=20–30
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    12.100/6.764/3.781 s per item, \times N total
    (a) Window set by a physical parameter (Tab. 15) Note
    t_{o}=3.025 s/item. Adults move one block over a partition in 0.72–0.78 s [78]; hard is 4.8–5.2\times that, as each sample is also aligned to a marker axis. Order of magnitude only.
Table 18: Time-parameter provenance: Healthcare. (a) Tasks whose window is set by a physical parameter of the scene (Tab. 15); their values are not sourced. (b) Tasks with a time limit (Tab. 16) and Throughput tasks; each value is compared with a documented real-world time.
  • A1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Drip-chamber level band
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    40–55 %, all levels
    (a) Window set by a physical parameter (Tab. 15) Note
    Design setting near the usual one-third to one-half fill; the level rate sets the window below.
  • A1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Window: level inside the band, counted from the robot’s own opening of the clamp
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    6 / 4.5 / 3 s
    (a) Window set by a physical parameter (Tab. 15) Note
    The level is still until the clamp is opened and reaches the band 3–5 s later (seeded).
  • A2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Window: bag 1 empty until its drip chamber runs dry (two 100 mL bags, gravity, wide open)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    8 / 5.5 / 3 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Set by the drawn chamber (about 79 mL) and the gravity flow; bag 1 empties 5–7.5 s into the episode (seeded).
  • A3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Breath period (4 breaths)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    6 s (10/min), all levels
    (a) Window set by a physical parameter (Tab. 15) Note
    One beat every 6 s on the on-screen timer; the first beat comes 7–9 s into the episode (seeded).
  • A3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Window around each beat
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    3 / 2 / 1 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Hard keeps every interval within 5–7 s; easy allows 3–9 s. Our squeeze takes 0.65 s.
  • (b) Time limit or throughput tier (Tab. 16)
  • Task
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Parameter
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15) Note
    Source and relation to our value
  • A4
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Limit, instruction to end of START press (bag spiked and hung first)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    26.64 / 14.9 / 8.33 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Easy (4t, oracle 6.66 s) is close to the 26.5 s mean critical-care nurses took, after training, to program a secondary antibiotic infusion on the fastest of three pumps (36.6 and 58.8 s on the others, up to 101 s before training) [45]; ours also spikes and hangs the bag.
  • B1–B6
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Cue onset (alarm, arrest, break, disconnection or bleeding)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    4–10 s (seeded)
    (a) Window set by a physical parameter (Tab. 15) Note
    Randomized per seed, as reaction-time studies vary the foreperiod “to prevent anticipation” [38]; real alarms and arrests are likewise unannounced.
  • B1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Ordered oxygen flow (simple face mask), float held 0.5 s
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    5, 6 or 7 L/min \pm1 (by seed), all levels
    (a) Window set by a physical parameter (Tab. 15) Note
    Inside the 5–10 L/min initial flow for a simple face mask in the BTS guideline [88]; the alarm fires when SpO2 crosses 90 %, below the guideline’s 94–98 % target range.
  • B1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    SpO2 fall before and after the alarm; recovery
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    0.12 and 0.6 %/s; 2.5 %/s after 0.8 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Before the alarm the fall runs at the real rate: an apnoeic patient on room air desaturates in 45–60 s [128], about 6 % in 50 s, and the episode starts mid-fall, 0.5–1.2 % above the alarm line. The rate after the alarm and the recovery are design settings: saturation is to be observed for at least 5 min after an increase [88], while ours recovers in about 4 s, after the scored response.
  • B1
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Response limit, alarm to float settled in the band
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    55 / 16.9 / 5.19 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Easy is the median 55 s after which nurses outside the room reached critical alarms, over half of them desaturations (26 % were answered within 90 s) [62]. Hard is from the oracle (4.15 s, about 2.45 s of it the reach).
  • B2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    AED analysis and charge, pads on to SHOCK ready
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    8 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Matches “typically in 8 seconds” [94]; one other AED is ready within at most 12 s [142].
  • B2
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Response limit, arrest to shock, incl. the 8 s analysis (seeded range)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    92.52–97.52 / 51.73–56.66 / 28.92–32.92 s
    (a) Window set by a physical parameter (Tab. 15) Note
    In-situ in-hospital simulations: AED arrival to first shock about 122 s (difference of medians) [114]; ours is 1.3–4.2\times shorter (AED at hand, no power-on). Oracle 23.13 s; easy 4t at the low end of the range.
  • B3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Response limit, break to both glass pieces in the sharps bin (seeded range)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    58.44–64.44 / 32.68–37.88 / 18.27–22.27 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Spills “must be contained and cleaned immediately” [121], no time given. In surprise drills with a broken vial, trained pharmacy staff took a mean 11.9 min (17.3 min before training) for the whole procedure [43]; our two steps are limited to 11–39\times less (oracle t=14.61 s; easy 4t at the low end of the range).
  • B3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Containment deadline (towel on the puddle), 0.4\times the response limit
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    23.38–25.78 / 13.07–15.15 / 7.31–8.91 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Spills “must be contained and cleaned immediately” [121], with no time given; trained staff took a mean 11.9 min for a whole broken-vial spill drill [43], 28–98\times our containment step (order of magnitude only). The puddle reaches its full 0.10 m radius at the deadline; the oracle lays the towel by 4.35 s.
  • B4
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Response limit, disconnection to elbow reseated, released and retained
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    20 / 8.87 / 3.93 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Easy is the adult default apnoea interval of an ICU ventilator (20 s) [27], close to the 23.3 s that logged alarms for unintended disconnections lasted on average (10–55 s) [32]; medium and hard are below the shortest logged alarm. All end before room-air apnoea desaturates (45–60 s) [128]. Hard from the oracle (3.14 s).
Table 19: Time-parameter provenance: Healthcare (continued).
  • B5
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Hold after the auto-injector fires
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    3 s, all levels
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    The device’s own instruction: “firmly push the orange tip … against the outer thigh and hold in place for 3 seconds”, at 90∘ to the thigh, through clothing if necessary [124].
  • B5
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Response limit, low-blood-pressure alarm to end of the 3 s hold
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    33.7 / 17.05 / 8.63 s
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Easy is the mean 33.72 s untrained adults took to give an EpiPen in a simulated emergency (Jext 29.21 s, Emerade 14.73 s) [68]; clinical teams took a median 95 s (IQR 77–252) with an auto-injector in in-situ simulations [77]. Guidance gives no time: adrenaline is first-line and given early [101]. Hard is from the oracle (6.90 s at the farthest tray-to-pad placement, 3 s of it the hold).
  • B5
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Systolic fall before and after the alarm; recovery after the dose
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    0.1 and 1 mmHg/s; 12 mmHg/s after 1 s
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Before the alarm the pressure falls on the scale of the sources, minutes from baseline to the alarm: fatal reactions to injected drugs reached arrest after a median 5 min [97]; the episode starts mid-fall, within 1 mmHg of the alarm line. The fall after the alarm and the recovery are design settings; the recovery, shown after the scored response, is faster than the 8\pm2 min to peak plasma adrenaline [113].
  • B6
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Windlass travel to the retaining clip (seeded); bleeding stopped
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    164–196∘; 30∘ before the clip, all levels
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    One 180∘ windlass turn occludes a correctly strapped Combat Application Tourniquet, and the rod is secured in the clip “at a rotation beyond that at which bleeding is stopped” [125]. The \pm16∘ spread (rod start and clip angles) and the 30∘ are design settings.
  • B6
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Bleeding rate with the windlass untwisted
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    4 mL/s, all levels
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    A thigh bleeding trainer lost 99\pm17 mL of simulated blood during a 24\pm4 s application, 4.1 mL/s [69]. Falls linearly to zero 30∘ before the clip (design).
  • B6
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Response limit, bleeding onset to rod released in the clip (0.3 s dwell)
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    24 / 11.43 / 5.44 s
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Easy is the 24\pm4 s experienced providers took to apply the tourniquet to a thigh trainer, timed until the windlass was secured [69]; ours starts with the band placed. Hard from the oracle (4.35 s). Severe bleeding can kill “in as little as five minutes” [3].
  • C1
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Budget, 8 vials into 4 order bins; t_{o}=16.09 s
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    64.4 / 36.0 / 20.1 s (8.0 / 4.5 / 2.5 s per vial)
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Pick-to-light reaches 300–1200 lines/h, 3–12 s per line [22]: easy, medium inside, hard 1.2\times faster. Pharmacists: median 60 s per prescription [118].
  • C2
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Budget, 6 instruments into tray slots; t_{o}=18.27 s
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    73.1 / 40.9 / 22.8 s (12.2 / 6.8 / 3.8 s per item)
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Central-processing records give a mean 17.7 s to pack one instrument into a surgical tray (7.6–31.6 s) [20]; ours are 1.5 / 2.6 / 4.7\times faster (no inspection). A vendor reports 15–28 min per whole tray [115].
  • C3
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Budget, 12 vials into drawer lanes; t_{o}=28.44 s
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    113.8 / 63.6 / 35.5 s (9.5 / 5.3 / 3.0 s per vial)
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Pharmacy technicians restocked an automated dispensing cabinet in 11.5 s per restock (21.3 s after a layout change) [63]; ours are 1.2 / 2.2 / 3.8\times faster per vial.
  • C4
    (b) Time limit or throughput tier (Tab. 16; continued) Parameter
    Budget, 12 tubes into 3 racks by stopper color; t_{o}=26.34 s
    (b) Time limit or throughput tier (Tab. 16; continued) Value (E/M/H)
    105.4 / 58.9 / 32.9 s (410 / 733 / 1313 tubes/h)
    (b) Time limit or throughput tier (Tab. 16; continued) Source and relation to our value
    Automated sorters are rated up to 1150 [112] and 1400 tubes/h [104]; hard lies between them, easy and medium are 0.3–0.6\times those rates.
Table 20: Time-parameter provenance: Household. (a) Tasks whose window is set by a physical parameter of the scene (Tab. 15); their values are not sourced. (b) Tasks with a time limit (Tab. 16) and Throughput tasks; each value is compared with a documented real-world time.
  • Task
    (a) Window set by a physical parameter (Tab. 15)
    Parameter
    (a) Window set by a physical parameter (Tab. 15)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15)
    Note
  • A1
    (a) Window set by a physical parameter (Tab. 15)
    Sugar in the glass when the jar is set down (gram band)
    (a) Window set by a physical parameter (Tab. 15)
    10–30 / 10–25 / 10–15 g
    (a) Window set by a physical parameter (Tab. 15)
    About 2.4–7.1 / 2.4–6.0 / 2.4–3.6 teaspoons; the only cue is the visible sugar heap.
  • A1
    (a) Window set by a physical parameter (Tab. 15)
    Sugar flow once the jar tilts past its onset (40–60∘, later when emptier) oracle: pours at 2.5 g/s, stops at the band middle
    (a) Window set by a physical parameter (Tab. 15)
    \leq4 g/s at full tilt, \times0.85–1.15 per seed, same at every tier
    (a) Window set by a physical parameter (Tab. 15)
    At the fastest pour the hard band lasts \geq1.09 s (5 g at 4.6 g/s), the 1 s floor.
  • A1
    (a) Window set by a physical parameter (Tab. 15)
    Spill limit
    (a) Window set by a physical parameter (Tab. 15)
    2 g
    (a) Window set by a physical parameter (Tab. 15)
    Design setting.
  • A2
    (a) Window set by a physical parameter (Tab. 15)
    Cube interval while the paddle is held oracle: releases 0.6 s after the last cube
    (a) Window set by a physical parameter (Tab. 15)
    2.0 / 1.5 / 1.3 s nominal; per seed \times0.93–1.13, \pm5 % jitter
    (a) Window set by a physical parameter (Tab. 15)
    H is capped at 1.15\times the M rate so that the release window (first cube in the band to the next cube) is at least 1 s (1.61 / 1.21 / 1.08 s worst case).
  • A2
    (a) Window set by a physical parameter (Tab. 15)
    Spin-up to first cube; run-on after release
    (a) Window set by a physical parameter (Tab. 15)
    0.6–1.3 s (M, \div tier scale); 0.12 s (M)
    (a) Window set by a physical parameter (Tab. 15)
    Simulation settings of the dispenser.
  • A2
    (a) Window set by a physical parameter (Tab. 15)
    Ice per cube; mass rate
    (a) Window set by a physical parameter (Tab. 15)
    8.5 g; 4.3 / 5.7 / 6.5 g/s
    (a) Window set by a physical parameter (Tab. 15)
    Mass rate = cube mass / cube interval above.
  • A3
    (a) Window set by a physical parameter (Tab. 15)
    Pan heat: underside browning 0.55–0.75 (hidden \tau 50–80 s, start age 15–25 s), browning rate \times1 / 1.33 / 2 oracle: flips \leq9.8 s after band entry (H)
    (a) Window set by a physical parameter (Tab. 15)
    flip window 42.5–93.5 / 31.9–70.1 / 21.3–46.7 s nominal
    (a) Window set by a physical parameter (Tab. 15)
    First side golden after 69–120 / 52–90 / 35–60 s; easy is set to a common recipe time (about 2 min), medium and hard are a hotter pan.
  • B1
    (a) Window set by a physical parameter (Tab. 15)
    Faucet flow, lever fully open
    (a) Window set by a physical parameter (Tab. 15)
    4.5 / 6.0 / 8.3 L/min
    (a) Window set by a physical parameter (Tab. 15)
    H equals the US maximum kitchen-faucet flow (2.2 gpm).
  • B1
    (a) Window set by a physical parameter (Tab. 15)
    Room left in the bowl; task fails at 0.5 L spilled oracle: flow stopped at 2.42 s
    (a) Window set by a physical parameter (Tab. 15)
    0.8–1.4 L of a 1.62 L bowl
    (a) Window set by a physical parameter (Tab. 15)
    Overflow after 10.7–18.7 / 8–14 / 5.8–10.1 s; earliest overflow in oracle runs 6.57 s (H).
  • B2
    (a) Window set by a physical parameter (Tab. 15)
    Board slope oracle: stops the object \geq4.4 cm from the edge
    (a) Window set by a physical parameter (Tab. 15)
    4.5 / 6 / 9∘
    (a) Window set by a physical parameter (Tab. 15)
    Rolling under gravity with damping: 1.2–2.3 s from release to the counter edge over objects and tiers (H {\approx}1.2 s). Real counters are level; the slope starts the roll.
  • B2
    (a) Window set by a physical parameter (Tab. 15)
    Release onset
    (a) Window set by a physical parameter (Tab. 15)
    U[1, 3] s
    (a) Window set by a physical parameter (Tab. 15)
    Randomized so the release cannot be anticipated.
  • B3
    (a) Window set by a physical parameter (Tab. 15)
    Pan-fire growth rate while the burner is on oracle: burner off at 5.6 s
    (a) Window set by a physical parameter (Tab. 15)
    \times0.75 / 1 / 1.5
    (a) Window set by a physical parameter (Tab. 15)
    Flame reaches 0.8 after 48–90 / 36–68 / 24–45 s (nominal 64 / 48 / 32 s).
  • B3
    (a) Window set by a physical parameter (Tab. 15)
    Flame decay after burner off
    (a) Window set by a physical parameter (Tab. 15)
    \tau=1 s
    (a) Window set by a physical parameter (Tab. 15)
    Abstraction: the flame dies out within a few seconds once the burner is off.
  • B3
    (a) Window set by a physical parameter (Tab. 15)
    Flame out for (success)
    (a) Window set by a physical parameter (Tab. 15)
    3 s
    (a) Window set by a physical parameter (Tab. 15)
    Confirms the fire stays out; design setting.
  • All
    (a) Window set by a physical parameter (Tab. 15)
    A2–B3 process-rate scale (rates \times, deadlines \div)
    (a) Window set by a physical parameter (Tab. 15)
    0.75 / 1 / 1.5
    (a) Window set by a physical parameter (Tab. 15)
    Design setting; deadlines shrink accordingly. A1 is tiered by its band only.
  • (b) Time limit or throughput tier (Tab. 16)
  • Task
    (a) Window set by a physical parameter (Tab. 15)
    Parameter
    (a) Window set by a physical parameter (Tab. 15)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15)
    Source and relation to our value
  • A4
    (a) Window set by a physical parameter (Tab. 15)
    Kettle pour flow at full tilt
    (a) Window set by a physical parameter (Tab. 15)
    \leq40 mL/s, \pm15 % per seed (300 g in \geq7.5 s)
    (a) Window set by a physical parameter (Tab. 15)
    Human volume-targeted pours take 3.2–8.7 s [55], the scale of our minimum pour; one measured gooseneck kettle peaks at 24 g/s [41], 1.7\times below ours.
  • A4
    (a) Window set by a physical parameter (Tab. 15)
    Budget: kettle set down and released, from t=0
    (a) Window set by a physical parameter (Tab. 15)
    115 / 64 / 36 s
    (a) Window set by a physical parameter (Tab. 15)
    A measured gooseneck kettle peaks at 24 g/s [41], so 300 g takes at least 12.5 s to pour; H allows 2.9\times that for reach, pour and set-down. Human volume-targeted pours take 3.2–8.7 s [55].
  • A4
    (a) Window set by a physical parameter (Tab. 15)
    Dose tolerance; read delay; scale display lag
    (a) Window set by a physical parameter (Tab. 15)
    \pm10 g; 3 s; 0.3 s
    (a) Window set by a physical parameter (Tab. 15)
    A bench scale settles in “2 seconds typical” [2]: our read delay is 1.5\times that, the display lag well inside it. The \pm10 g tolerance is a design setting (oracle error \leq1.7 g).
  • C1
    (a) Window set by a physical parameter (Tab. 15)
    Waiter pickups, 4 orders (stream); reference schedule 10.53+12.96\,k s
    (a) Window set by a physical parameter (Tab. 15)
    first 42.12 / 23.55 / 13.16 s, every 51.84 / 28.98 / 16.20 s; last 197.64 / 110.48 / 61.76 s
    (a) Window set by a physical parameter (Tab. 15)
    Reference = slowest oracle set-downs, \times4 / \sqrt{5} / 1.25. Analogy only: a fast-food drive-thru visit, line entry to leaving with food, averaged 5 min 43 s over ten US chains in 2023 [86]; our dishes are pre-made and the first pickup comes 8–26\times sooner.
  • C2
    (a) Window set by a physical parameter (Tab. 15)
    Six glasses, t_{o}=43.21 s
    (a) Window set by a physical parameter (Tab. 15)
    172.8 / 96.6 / 54.0 s
    (a) Window set by a physical parameter (Tab. 15)
    4/\sqrt{5}/1.25\,t_{o}. H leaves 9.0 s per glass (two arms); a balanced draught tap fills a pint in about 8 s [15], and human volume-targeted pours take 3.2–8.7 s [55].
  • C3
    (a) Window set by a physical parameter (Tab. 15)
    Six utensils, t_{o}=25.97 s
    (a) Window set by a physical parameter (Tab. 15)
    103.9 / 58.1 / 32.5 s
    (a) Window set by a physical parameter (Tab. 15)
    4/\sqrt{5}/1.25\,t_{o}. H leaves 5.4 s per utensil (two arms); one timed home load of 75 items (30 of them utensils) was dried and put away in 6 min 45 s, 5.4 s per item [24]; human shelf-stocking cycles take 1–4 s per item [105].
  • All
    (a) Window set by a physical parameter (Tab. 15)
    Release/settle dwells (jar and spoon in A1, glass, kettle, objects)
    (a) Window set by a physical parameter (Tab. 15)
    1 s
    (a) Window set by a physical parameter (Tab. 15)
    Half the “2 seconds typical” a bench scale needs to settle on a placed load [2]; ours confirms the object rests. Analogy only.
Table 21: Time-parameter provenance: Industry. (a) Tasks whose window is set by a physical parameter of the scene (Tab. 15); their values are not sourced. (b) Tasks with a time limit (Tab. 16) and Throughput tasks; each value is compared with a documented real-world time.
  • A2 (42)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Rotary accumulation table speed
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    5∘/s (0.83 rpm), all levels
    (a) Window set by a physical parameter (Tab. 15) Note
    A part takes 72 s per turn; with the sector below it sets the loading window.
  • A2 (42)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Loading-sector width
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    60 / 50 / 40∘
    (a) Window set by a physical parameter (Tab. 15) Note
    12 / 10 / 8 s to load the part before the sector passes.
  • A2 (42)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Table start angle (seed-drawn)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    \pm10∘
    (a) Window set by a physical parameter (Tab. 15) Note
    Shifts the loading window by \pm2 s so it cannot be anticipated.
  • (b) Time limit or throughput tier (Tab. 16)
  • Task
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Parameter
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15) Note
    Source and relation to our value
  • A1 (41)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Minimum zincate-dip immersion (process_min_s), from full immersion of the part picked from the loading pad
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    18–22 s (seed), all levels
    (a) Window set by a physical parameter (Tab. 15) Note
    Zincate dips last 20–120 s [106], 20–50 s for the first dip of a double-zincate cycle [122]; our 18–20 s draws are up to 10% shorter.
  • A1 (41)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Exit-window width after the minimum
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    28 / 16.85 / 10.14 s
    (a) Window set by a physical parameter (Tab. 15) Note
    The patent’s first-dip range of 20–50 s spans 30 s [122]; easy (28 s) is 0.93\times that span and closes at most 50 s after immersion, hard is a third of it. Oracle exit 22.10–25.64 s after immersion.
  • A3 (43)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Seating window opens after bead end
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    2 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Corrugated-packaging hot melts are specified with open times in classes of 1–3, 3–5 and 5–15 s, the time within which the flaps are mated [14]; our earliest seating at 2 s lies inside the 1–3 s class. Analogy only: it gives the dispenser time to clear.
  • A3 (43)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Seating window closes after bead end
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    40 / 25.67 / 16.47 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Easy is the longest documented hot-melt open time, 40 s [1] (shortest {<}15 s [56]); data-sheet open time runs from application, ours from bead end. Oracle t{=}13.17 s.
  • B1 (44)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Coolant leak flow
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    0.14 L/s
    (a) Window set by a physical parameter (Tab. 15) Note
    Matches a 1/8 in hole at 60 psi (2.28 gpm = 0.144 L/s) [9].
  • B1 (44)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Spill-tray limit / capacity
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    2.0 / 2.6 L
    (a) Window set by a physical parameter (Tab. 15) Note
    Smallest commercial tray opened holds 11.5 L [67], 4.4\times ours. The limit is reached {\approx}14 s after onset, which caps the easy deadline.
  • B1 (44)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Valve fully closed after leak onset
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    14 / 9.38 / 6.28 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Oracle t{=}5.02 s; easy is capped by the tray limit (4t would be 20.1 s). Actuated quarter-turn valves stroke in 0.5–6 s [90, 44]; ours is 1.05–2.3\times the 6 s maximum and adds detection and reach. LOPA credits a manual response only if \geq20 min are available [16].
  • B2 (45)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Stop button actuated after warning
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    3 / 2.75 / 2.53 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Measured e-stop presses: means 0.2–0.9 s, hand near the button [40]; ours is 2.8–3.3\times the slowest mean (0.91 s). Oracle t{=}2.02 s.
  • B3 (46)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Outfeed belt speed
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    0.35 m/s (0.33–0.37)
    (a) Window set by a physical parameter (Tab. 15) Note
    Standard unit-handling conveyor speed 65 ft/min = 0.33 m/s [23]; nominal 6 % faster.
  • B3 (46)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Slope of the gravity lane through the 0.3 m safety zone
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    8.2∘
    (a) Window set by a physical parameter (Tab. 15) Note
    An un-braked bearing crosses the zone in 0.74–0.79 s, so the brake must be in the lane by then at every level. A gravity roller conveyor is specified with a 7–10∘ decline for products under 5 lb [30]; ours lies inside.
  • B3 (46)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Stable arrest after zone entry
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    4.77 / 2.67 / 1.50 s
    (a) Window set by a physical parameter (Tab. 15) Note
    A conveyor drum-motor brake closes 13–500 ms after power is cut [60]; ours is 3–9.5\times the slowest closing and includes detection, reach and settling (oracle t{=}1.19 s; easy 4t). Analogy only.
  • A3, B1–B3
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Event onsets (seed-drawn)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    bead end 16–20 s; leak 20–24 s; warning 14–18 s; gate 7–9 s
    (a) Window set by a physical parameter (Tab. 15) Note
    A variable foreperiod prevents anticipation: with a fixed one, a simple response can be fully prepared in advance [8]. Our onsets vary over 2–4 s.
  • C1 (47)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Two maintenance kits (6 parts)
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    t_{o}{=}64.50 s; 258.0 / 144.2 / 80.6 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Hard allows 13.4 s per part (two arms), 2.6\times the 5.06–5.16 s per component modelled for manual and cobot-supported kit preparation [33]; human warehouse pickers take 5–10 s per item [26].
  • C2 (48)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Three cartons shelved
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    t_{o}{=}45.32 s; 181.3 / 101.3 / 56.6 s
    (a) Window set by a physical parameter (Tab. 15) Note
    18.9 / 33.8 / 60.4 s per carton, inside the 6.9–124 s per case of manual full-case picking (525 to 29 cases per man-hour); man-up order picking takes 26.9 s (134 cases/h) [116].
  • C3 (49)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Three parts weighed and sorted
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    t_{o}{=}69.36 s; 277.4 / 155.1 / 86.7 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Hard allows 28.9 s per part, 4.7–4.8\times a kitting move (5.06–5.16 s per component [33]) plus a 1 s scale stabilisation [89]. Analogy only: no weigh-and-sort cycle time found.
  • C3 (49)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Part at rest on the pan before a reading counts; display settling
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    0.5 s; within 2 g over 0.4 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Checkweighers should stabilise in under 0.5 s, one model in 0.43 s [6]; a bench scale states 1 s [89]. Our 0.4 s settling matches the former, rest plus settling (0.9 s) the latter. Underweight parts weigh 70 % of nominal (105 vs. 150 g, PASS at \geq125 g).
  • C4 (50)
    (a) Window set by a physical parameter (Tab. 15) Parameter
    Two four-pan palettes
    (a) Window set by a physical parameter (Tab. 15) Value (E/M/H)
    t_{o}{=}81.46 s; 325.8 / 182.2 / 101.8 s
    (a) Window set by a physical parameter (Tab. 15) Note
    Hard allows 10.2 s per placement (8 pans, 2 cases), 2.0\times the 5.06–5.16 s per kitted component [33] and at the upper end of 5–10 s per picked item [26]; analogy only.
Table 22: Time-parameter provenance: Sports & games. (a) Tasks whose window is set by a physical parameter of the scene (Tab. 15); their values are not sourced. (b) Tasks with a time limit (Tab. 16) and Throughput tasks; each value is compared with a documented real-world time.
  • Task
    (a) Window set by a physical parameter (Tab. 15)
    Parameter
    (a) Window set by a physical parameter (Tab. 15)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15)
    Note
  • B4
    (a) Window set by a physical parameter (Tab. 15)
    RED to confirmed rest of hands, tools and puck
    (a) Window set by a physical parameter (Tab. 15)
    8 / 4 / 2 s
    (a) Window set by a physical parameter (Tab. 15)
    Time allowed to come to rest in each red phase; oracle t\leq 0.136 s. Each red lasts the limit plus a seeded 2.2–3.2 s hold.
  • B5
    (a) Window set by a physical parameter (Tab. 15)
    Note window, symmetric about the note
    (a) Window set by a physical parameter (Tab. 15)
    \pm2.0 / 1.41 / 1.0 s
    (a) Window set by a physical parameter (Tab. 15)
    Hard is the 1 s floor. Oracle strikes 0.104 s early: hard margin 0.896 s.
  • B5
    (a) Window set by a physical parameter (Tab. 15)
    Note interval; first note (8 notes)
    (a) Window set by a physical parameter (Tab. 15)
    5 s; 12 s
    (a) Window set by a physical parameter (Tab. 15)
    Wide enough that windows never overlap.
  • (b) Time limit or throughput tier (Tab. 16)
  • Task
    (a) Window set by a physical parameter (Tab. 15)
    Parameter
    (a) Window set by a physical parameter (Tab. 15)
    Value (E/M/H)
    (a) Window set by a physical parameter (Tab. 15)
    Source and relation to our value
  • A1
    (a) Window set by a physical parameter (Tab. 15)
    Clock-press deadline after the opponent’s press
    (a) Window set by a physical parameter (Tab. 15)
    30 / 17 / 10 s
    (a) Window set by a physical parameter (Tab. 15)
    Oracle t=7.90 s. Easy equals the common 30 s Fischer increment [35]; hard equals the 10 s increment of the World Rapid Championship and is 5\times the 2 s blitz increment [36]. An increment is added thinking time, not a deadline.
  • A2
    (a) Window set by a physical parameter (Tab. 15)
    Shot clock, READY to release
    (a) Window set by a physical parameter (Tab. 15)
    14 / 9 / 6 s
    (a) Window set by a physical parameter (Tab. 15)
    Oracle t=4.59 s, grasp included. Easy equals the FIBA 14 s shot-clock reset [58]; FIBA’s 5 s free-throw limit (ball already in hand) is below our hard.
  • A2
    (a) Window set by a physical parameter (Tab. 15)
    Flight grace after release
    (a) Window set by a physical parameter (Tab. 15)
    4 s
    (a) Window set by a physical parameter (Tab. 15)
    Successful free throws of 20 league players took 1.11 s (0.91–1.55 s) from release to the basket [64]; ours is 3.6\times the mean. Our 0.3 m-apex lob flies {\approx}0.5 s (ballistics, our estimate).
  • A2
    (a) Window set by a physical parameter (Tab. 15)
    READY onset after the start
    (a) Window set by a physical parameter (Tab. 15)
    U[2, 6) s
    (a) Window set by a physical parameter (Tab. 15)
    Randomized so the onset cannot be anticipated: with a variable foreperiod, the moment of the signal is uncertain, whereas a fixed one can be anticipated [51, 38].
  • B1
    (a) Window set by a physical parameter (Tab. 15)
    Mole time-up, from its rise
    (a) Window set by a physical parameter (Tab. 15)
    4.0 / 3.0 / 2.2 s
    (a) Window set by a physical parameter (Tab. 15)
    Oracle t=1.756 s. Easy is capped at the 4 s between moles (4t would be 7.0 s). Lab whack-a-mole tasks show targets for 1.8 s [82] and 1.25 s [85]; ours are 1.2–3.2\times longer. Arcade manual states no unit [13].
  • B1
    (a) Window set by a physical parameter (Tab. 15)
    Mole spacing; moles per episode
    (a) Window set by a physical parameter (Tab. 15)
    4.0 s; 9 ({\approx}1/3 decoys)
    (a) Window set by a physical parameter (Tab. 15)
    Between the 2.3 s trial of the Inquisit go/no-go task and the 1.5 s stimulus plus 5 s interval of the study it reproduces [82].
  • B2
    (a) Window set by a physical parameter (Tab. 15)
    GO cue to pad hit
    (a) Window set by a physical parameter (Tab. 15)
    1.6 / 1.25 / 1.0 s
    (a) Window set by a physical parameter (Tab. 15)
    Oracle t=0.680 s. Easy is capped by the cue schedule: the next cue of a combination follows 2.8–3.5 s later, so hit and return share about 3 s. Boxers’ punch delivery takes 0.36–0.66 s, cue reaction excluded [95, 37]; hard is 1.5–2.8\times that.
  • B2
    (a) Window set by a physical parameter (Tab. 15)
    Hit to glove back in guard
    (a) Window set by a physical parameter (Tab. 15)
    1.4 / 1.2 / 1.05 s
    (a) Window set by a physical parameter (Tab. 15)
    Oracle t=0.716 s. In four-punch combinations, boxers went from the first to the fourth contact in 1.04–1.35 s, about 0.35–0.45 s per punch-and-recovery cycle [95]; our hard is 2.3–3\times that. Analogy only: no isolated return-to-guard time found.
  • B3
    (a) Window set by a physical parameter (Tab. 15)
    Catch deadline, from bar descent
    (a) Window set by a physical parameter (Tab. 15)
    2.05 / 1.43 / 1.0 s
    (a) Window set by a physical parameter (Tab. 15)
    Oracle t=0.512 s; easy 4t; hard is the 1 s floor. The fatigued lifter lowers the bar at 5 cm/s, so it stays above the danger height for 3.2–5.3 s. IPF rules let spotters take a failing bar but set no time [59]. Hands-in-place catch reactions take 0.18–0.25 s [31]; our hard is 4–5.6\times that.
  • B3
    (a) Window set by a physical parameter (Tab. 15)
    Lifter stall before the drop
    (a) Window set by a physical parameter (Tab. 15)
    0.65–1.1 s (seeded)
    (a) Window set by a physical parameter (Tab. 15)
    Brackets the {\approx}0.8 s bench-press sticking region quoted in [123]; that is a slowdown at near-maximal load, not a stall.
  • C1
    (a) Window set by a physical parameter (Tab. 15)
    Time tier to rack 15 balls
    (a) Window set by a physical parameter (Tab. 15)
    510.0 / 285.1 / 159.4 s
    (a) Window set by a physical parameter (Tab. 15)
    t_{o}=127.49 s; tiers 4, \sqrt{5}, 1.25\times t_{o}. Adults 40 and older move 61–83 blocks a minute one at a time in the Box and Block Test [109], so 15 transfers take 11–15 s; hard allows 11–15\times that. Analogy only: no racking time found.
  • C2
    (a) Window set by a physical parameter (Tab. 15)
    Time tier for 2 cards, after 2 s preparation
    (a) Window set by a physical parameter (Tab. 15)
    125.6 / 70.2 / 39.3 s
    (a) Window set by a physical parameter (Tab. 15)
    t_{o}=31.41 s. Speed Cups is an untimed race [4]; a 12-cup sport-stacking record cycle takes 4.7 s [49], while hard allows 19.6 s per card of 6 cups. At Box and Block rates [109] 6 transfers take 4.3–5.9 s.
  • C3
    (a) Window set by a physical parameter (Tab. 15)
    Ball demands: first demand; firing interval (6 demands)
    (a) Window set by a physical parameter (Tab. 15)
    21.65 / 13.20 / 8.05 s; 12.00 / 7.32 / 4.46 s
    (a) Window set by a physical parameter (Tab. 15)
    Reference 6.44 s + 3.57 s per demand, \times3.361 / 2.050 / 1.25. Easy is capped at a ball machine’s slowest feed, 12 s (range 2–12 s) [76].

Appendix E Temporal Difficulty Study

We ran Gemini 4 Argon through Tool-augmented EEF on all 60 tasks at the medium and hard levels, on seeds 0–9 for every task (600 episodes per level; rates are averaged within each task first). PSR and TSR are measured with inference paused, and LTSR in Latency-Aligned mode with the measured API latency and \delta=20 ms; the easy row repeats Tab. 26 (Tab. 23). Because the levels tighten only the temporal parameters, PSR stays between 22.5 and 28.0%, while overall TSR falls from 18.2% at easy and 18.8% at medium to 11.3% at hard, mostly in Temporal Window (20.5 to 16.8%) and Event-Reactive tasks (24.6 to 14.2%). LTSR falls from 8.2% at easy to 3.3% and 1.5%. The API serving speed may differ between the easy run and the later medium and hard runs, so the LTSR comparison across levels is indicative only.

Table 23: Gemini 4 Argon through Tool-augmented EEF on all 60 tasks at the three difficulty levels (10 seeds per task, 0–9). PSR and TSR with inference paused; LTSR with measured API latency. Easy: Tab. 26. A/B/C: Temporal Window, Event-Reactive, Throughput; metrics in %, macro-averaged over tasks; Overall is weighted by the 19/24/17 tasks of A/B/C.
  • Easy
    A PSR
    24.7
    A TSR
    20.5
    A LTSR
    10.5
    B PSR
    36.3
    B TSR
    24.6
    B LTSR
    12.1
    C PSR
    7.6
    C TSR
    6.5
    C LTSR
    0.0
    Overall PSR
    24.5
    Overall TSR
    18.2
    Overall LTSR
    8.2
  • Medium
    A PSR
    34.7
    A TSR
    27.4
    A LTSR
    6.3
    B PSR
    40.0
    B TSR
    24.2
    B LTSR
    3.3
    C PSR
    3.5
    C TSR
    1.8
    C LTSR
    0.0
    Overall PSR
    28.0
    Overall TSR
    18.8
    Overall LTSR
    3.3
  • Hard
    A PSR
    27.4
    A TSR
    16.8
    A LTSR
    1.1
    B PSR
    30.0
    B TSR
    14.2
    B LTSR
    2.9
    C PSR
    6.5
    C TSR
    1.2
    C LTSR
    0.0
    Overall PSR
    22.5
    Overall TSR
    11.3
    Overall LTSR
    1.5

Appendix F Agent Behavior, Cost, and Per-Task Variation

Tab. 24 reports interaction costs for a six-model diagnostic subset under zero latency: model turns per episode, output tokens per turn, and API cost per episode.

Table 24: Interaction cost of VLM agents (six-model diagnostic subset under zero latency, 10 seeds per task). Turns: model calls per episode. Tok: output tokens per turn, reasoning included. $: API cost per episode (USD). †open-weight; §text-only.
  • Gemini 4 Argon
    Turns
    16.1
    Tok
    681
    $
    0.35
  • Claude Opus 5.5
    Turns
    23.0
    Tok
    770
    $
    0.57
  • GPT-6 Astra
    Turns
    51.2
    Tok
    160
    $
    1.58
  • GPT-6.1 Sol
    Turns
    43.0
    Tok
    163
    $
    0.24
  • DeepSeek V4.1 Flash†
    Turns
    66.3
    Tok
    2821
    $
    0.16
  • GLM-5.3†§
    Turns
    28.7
    Tok
    416
    $
    0.13

F.1 Effect of API Serving Speed on LTSR

Latency-Aligned evaluation charges each query’s round trip, so the LTSR of an API-served agent depends on the serving speed. Table 25 compares measured serving rates of 18 and 26 tokens/s for GPT-6 Astra (Microsoft Azure), and 22 and 36 tokens/s for Gemini 4 Argon (Google Cloud).

Table 25: LTSR (%) of API-served VLM agents at different measured serving rates. Each model appears at two decoding rates; tok/s: average decoding rate of the API during the evaluation. GPT-6 Astra is served through Microsoft Azure and Gemini 4 Argon through Google Cloud. Overall is weighted by the 19/24/17 tasks of categories A/B/C.
  • GPT-6 Astra
    tok/s
    18
    A
    0.0
    B
    2.1
    C
    0.0
    Overall
    0.8
  • 26
    tok/s
    5.8
    A
    2.9
    B
    0.0
    C
    3.0
  • Gemini 4 Argon
    tok/s
    22
    A
    0.0
    B
    2.5
    C
    0.0
    Overall
    1.0
  • 36
    tok/s
    10.5
    A
    12.1
    B
    0.0
    C
    8.2

Faster serving raises LTSR from 0.8% to 3.0% and from 1.0% to 8.2%, through tasks whose windows leave more than one model turn; tasks that must be answered within a few seconds stay at zero. Gemini gains more because it needs fewer turns (a median of 3 against 6 per successful episode). LTSR of API-served agents should therefore be reported with the provider and serving speed; Tab. 5 reports the faster serving.

Results with faster API serving.

Tab. 26 repeats the rows of Tab. 5 for the four API-served models, which are the simulated values used in the comparison with the real robot in App. L.

Table 26: Results of four API-served VLM agents through Tool-augmented EEF, with faster API serving and latency charged in closed loop (easy level). A/B/C: Temporal Window, Event-Reactive, Throughput; metrics in %, macro-averaged over tasks; all values are those of Tab. 5, and Overall is weighted by the 19/24/17 tasks of A/B/C. Bold: best.
  • Gemini 4 Argon
    A PS
    41.1
    A PSR
    24.7
    A TSR
    20.5
    A LTSR
    10.5
    B PS
    40.4
    B PSR
    36.3
    B TSR
    24.6
    B LTSR
    12.1
    C PS
    21.8
    C PSR
    7.6
    C TSR
    6.5
    C LTSR
    0.0
    Overall PS
    35.3
    Overall PSR
    24.5
    Overall TSR
    18.2
    Overall LTSR
    8.2
  • GPT-6 Astra
    A PS
    43.7
    A PSR
    28.4
    A TSR
    22.1
    A LTSR
    5.8
    B PS
    40.8
    B PSR
    34.6
    B TSR
    30.0
    B LTSR
    2.9
    C PS
    18.8
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    35.5
    Overall PSR
    22.8
    Overall TSR
    19.0
    Overall LTSR
    3.0
  • GPT-6.1 Sol
    A PS
    38.9
    A PSR
    27.4
    A TSR
    24.2
    A LTSR
    1.6
    B PS
    37.1
    B PSR
    32.9
    B TSR
    24.2
    B LTSR
    4.6
    C PS
    15.3
    C PSR
    0.0
    C TSR
    0.0
    C LTSR
    0.0
    Overall PS
    31.5
    Overall PSR
    21.8
    Overall TSR
    17.3
    Overall LTSR
    2.3
  • Claude Opus 5.5
    A PS
    30.5
    A PSR
    17.4
    A TSR
    12.6
    A LTSR
    0.0
    B PS
    30.8
    B PSR
    26.7
    B TSR
    23.8
    B LTSR
    2.5
    C PS
    12.9
    C PSR
    1.2
    C TSR
    0.6
    C LTSR
    0.0
    Overall PS
    25.7
    Overall PSR
    16.5
    Overall TSR
    13.7
    Overall LTSR
    1.0
Decode-speed model behind Fig. 5.

The ablation of Sec. 6.2 replaces the measured latency of Eq. (1) with one derived from an assumed decoding rate:

\hat{L}_{\mathrm{infer},k}=\frac{N_{\mathrm{out},k}}{r_{\mathrm{dec}}},
(4)

where N_{\mathrm{out},k} is the number of output tokens of query k, reasoning included, and r_{\mathrm{dec}} the assumed rate (35 to 3K tokens/s). It omits prefill, network, and queueing time and keeps token counts fixed, so Fig. 5 shows the effect of decoding speed, not the LTSR of a particular deployment.

Appendix G Task Manifest and Event Semantics

Each task is specified by a manifest that fixes the scene, the robot, the observations, the temporal contract, and the physical goal. Every timed event is a predicate on physical state with fixed thresholds and is logged with its environment timestamp; temporal clauses are evaluated on these timestamps. Each window is anchored at its specified measured event: policy-triggered intervals move with the corresponding action, whereas external-event deadlines remain tied to the external trigger.

Appendix H Temporal Monitor Acceptance Checks

Before model evaluation, the temporal monitors are checked on reference and deliberately invalid traces: an action inside, before, or after its window, a missing or unanswered event, an interrupted contact, a unit counted twice, and a rolling interval below the required rate must each yield the intended outcome.

Appendix I Study Matrix

Physical versus temporal success and the temporal taxonomy are reported in Tabs. 2 and 5; fine-tuning and transfer in Tabs. 2 and 3; the action interface in Tab. 4; inference speed and latency across policy families in Secs. 6.2 and 6.3; and agent behavior in App. F.

Appendix J Dataset and Runtime Reporting

Each episode record stores the task, level, seed, instruction, timestamped events, score stages, violations, and termination reason, and per query the environment time, the measured and charged latency, and the output tokens. All methods use the same available sensor rig and robot-state streams, with model-specific input selection and preprocessing (Tab. 11 for the fine-tuned policies); the text-only GLM-5.3 reference receives no images. VLM agents read the task clock as text, fine-tuned policies receive it in the instruction, and only the oracle reads ground-truth state.

Appendix K Reproducibility

We will release the task manifests, assets, splits, seeds, monitors, oracles, demonstrations, baseline adapters, prompts, run configurations, and aggregation code. Healthcare and laboratory parameters are not operational safety limits.

Appendix L Real-Robot Pilot

This pilot carries the three temporal categories to a physical arm with six tasks (Tab. 27), scores six VLMs on them (App. L.1), and compares the resulting ranking with simulation.

Hardware.

One UFactory xArm 6 with a soft-finger gripper stands at a table. A RealSense D435 head camera across the table gives a 640\times 480 color image and a wrist camera an infrared image, both calibrated to the arm’s base frame. Unlike the simulated rig, there is a single arm and no depth image.

Control loop and interface.

The model and the arm exchange one observation and one command per turn. The arm side enforces inverse kinematics, joint and workspace limits, a table guard, and a watchdog; the tool moves at 30 mm/s, and an operator holds the emergency stop. An episode ends on finish, at the turn cap or 600 s, on a controller error, or on operator interruption.

The single-arm Tool-augmented EEF interface (App. B) has ten tools and one call per turn; a target is a base-frame point or a head-image pixel with a height above the table, and tool results are measurements only. Direct pose commands were used in all C2 episodes and most A2 and B2 episodes; the remaining episodes used the tool interface.

There is no paused clock on hardware, so success corresponds to LTSR. The median model reply takes 5.1 s, from 3.4 s for Qwen3.8 27B to 16.8 s for DeepSeek V4.1 Flash.

Six VLMs were run: GPT-6 Astra, GPT-6.1 Sol, Gemini 4 Argon, Claude Opus 5.5, DeepSeek V4.1 Flash, and Qwen3.8 27B. Logs store every model input and command, the robot state per turn, call times and costs, and 10 fps videos.

Table 27: The six real-robot tasks, grouped as in simulation. A: Temporal Window; B: Event-Reactive; C: Throughput. Top row: the scene, photographed from the side; in the B2 and C2 photographs the head camera is the one on the boom above the arm, and the board of fiducial markers at the left edge is used only for camera calibration. Second row: the first head-camera image of an episode, as the model sees it, with the arm’s base at the top. Third row: what the agent must do. Last two rows: the time requirement, which is 4\times the human standard time for A2, B1, C1, and C2 and the ringing duration of the alarm for B2; “–”: none applies. †A1 encodes its temporal stopping condition through the physical volume limit: pouring must stop before the amount exceeds 100 mL; no fixed duration is prescribed.
  • A1 Pour from a can. Grasp the open drinks can, carry it over the white bowl, tilt it toward the bowl, set it upright, and put it back where it stood.
    A2 Cube into box. Grasp the 50 mm tagged cube, lift it above the rim of the open storage box, and release it over the opening without touching the box.
    B: Event-Reactive
    B1 Lemon on red. A phone on the table shows colors at unpredictable moments. When it turns red, put the toy lemon into the basket. Any motion before red fails; other colors are distractors.
    B2 Alarm press. When the twin-bell alarm clock rings, press its top between the two bells with the closed fingertips, then retreat.
    C: Throughput
    C1 Fruits into basket. Put the four toy fruits (about 5 cm) into the basket with 10 cm walls, as many and as fast as possible.
    C2 Peg sorting. Move eight pegs in four colors from a raised stand into the 2\times 4 pegboard so that each column holds one color.
  • Temporal requirement
  • \leq 100 mL†
    12.8 s
    B: Event-Reactive
    8.4 s
    3 min (alarm rings)
    C: Throughput
    21.6 s
    72.8 s
  • Human standard time
  • –
    3.2 s
    B: Event-Reactive
    2.1 s
    –
    C: Throughput
    5.4 s
    18.2 s
Tasks.

A1 pours from an open can into a bowl, stops before the poured amount exceeds 100 mL, and returns the can to its starting position. A2 requires the cube to be released into the box within 12.8 s. In B1 a phone screen shows colors at unpredictable moments; after red, and only then, the lemon must go into the basket within 8.4 s. In B2 the agent presses the top of a ringing alarm clock within its 3 min ring. In C1 four rolling toy fruits go into a basket (21.6 s); in C2 eight pegs are sorted by color into a 2\times 4 pegboard (72.8 s). A2, B1, C1, and C2 use four times the human standard time. B2 uses the alarm ringing duration. A1 implements its temporal stopping condition through the physical volume limit rather than a fixed duration.

Case study: B1 across six models.

We ran B1 once per model and timed it from the red onset (Tab. 28). Every model waited for red, but the first motion came 5.0–11.5 s later, and the three models that delivered the lemon needed 45.8–78.1 s, far beyond the simulated Event-Reactive limits. Claude Opus 5.5 and Qwen3.8 27B grasped but did not deliver it, and DeepSeek V4.1 Flash never grasped it. With one episode per model, these runs illustrate behavior and do not rank the models.

Table 28: Case study on B1 (lemon on red), one episode per model. Start, Grasp, and Placed are seconds after the screen turned red, from the operator’s record; “–” means the step was not reached. PS: 50 for holding the lemon, 100 for the lemon in the basket. Frames are from the head camera: 0.5 s after the red onset, about 2 s after the first motion, about 2 s after the grasp (for DeepSeek V4.1 Flash, which never grasped, 30 s after the onset), and the end of the episode.
  • DeepSeek V4.1 Flash
    Start (s)
    4.97
    Grasp (s)
    –
    Placed (s)
    –
    PS
    0
  • GPT-6 Astra
    Start (s)
    6.61
    Grasp (s)
    16.86
    Placed (s)
    56.40
    PS
    100
  • Gemini 4 Argon
    Start (s)
    11.52
    Grasp (s)
    43.41
    Placed (s)
    78.07
    PS
    100
  • Claude Opus 5.5
    Start (s)
    9.38
    Grasp (s)
    23.64
    Placed (s)
    –
    PS
    50
  • Qwen3.8 27B
    Start (s)
    10.01
    Grasp (s)
    20.93
    Placed (s)
    –
    PS
    50
  • GPT-6.1 Sol
    Start (s)
    9.62
    Grasp (s)
    22.99
    Placed (s)
    45.77
    PS
    100

L.1 Scoring and Results

The operator scores every episode with the rubric of Tab. 29: PS sums the step points up to 100, PSR is the share reaching the final step, and LTSR the share that also meets the temporal requirement (for A1, stopping the pour before exceeding 100 mL). TSR is undefined on hardware. Each model runs 10 episodes per task, 360 in total.

Table 29: Step scoring of the real-robot tasks. Points add up to a PS of 100 per episode.
  • A1
    Steps and points
    Can picked up: 25. Held over the bowl: 25. Tilted: 25. Water flows into the bowl and the can is returned: 25.
    Task
    B2
    Steps and points
    Fingertips aligned over the alarm clock: 50. Top pressed: 50.
  • A2
    Steps and points
    Object picked up: 40. Held over the container: 40. Dropped into the container: 20.
    Task
    C1
    Steps and points
    Per fruit (four): picked up 10; placed in the basket 15.
  • B1
    Steps and points
    Grasped after the red cue: 50. Held over the basket: 20. Dropped into the basket: 30.
    Task
    C2
    Steps and points
    Per peg (eight): picked up 5; inserted 5. Per column holding two pegs of one color (four): 5.
Table 30: Real-robot results of six VLMs, scored by the operator with the rubric of Tab. 29. PS: mean step score; PSR: episodes that complete the task (%); LTSR: episodes that complete it while satisfying the temporal requirement, including the volume-defined stopping condition of A1 (%). Each entry is the mean over 10 episodes. Mean: unweighted mean over the six tasks. Bold: best per column.
  • Gemini 4 Argon
    A1 PS
    37.5
    A1 PSR
    20
    A1 LTSR
    20
    A2 PS
    100
    A2 PSR
    100
    A2 LTSR
    0
    B1 PS
    94
    B1 PSR
    80
    B1 LTSR
    0
    B2 PS
    75
    B2 PSR
    50
    B2 LTSR
    50
    C1 PS
    12.5
    C1 PSR
    0
    C1 LTSR
    0
    C2 PS
    3.5
    C2 PSR
    0
    C2 LTSR
    0
    Mean PS
    53.8
    Mean PSR
    41.7
    Mean LTSR
    11.7
  • GPT-6 Astra
    A1 PS
    60
    A1 PSR
    30
    A1 LTSR
    30
    A2 PS
    100
    A2 PSR
    100
    A2 LTSR
    0
    B1 PS
    79
    B1 PSR
    30
    B1 LTSR
    0
    B2 PS
    65
    B2 PSR
    30
    B2 LTSR
    30
    C1 PS
    21.5
    C1 PSR
    0
    C1 LTSR
    0
    C2 PS
    2.5
    C2 PSR
    0
    C2 LTSR
    0
    Mean PS
    54.7
    Mean PSR
    31.7
    Mean LTSR
    10.0
  • GPT-6.1 Sol
    A1 PS
    0
    A1 PSR
    0
    A1 LTSR
    0
    A2 PS
    50
    A2 PSR
    10
    A2 LTSR
    0
    B1 PS
    80
    B1 PSR
    40
    B1 LTSR
    0
    B2 PS
    40
    B2 PSR
    10
    B2 LTSR
    0
    C1 PS
    3
    C1 PSR
    0
    C1 LTSR
    0
    C2 PS
    0
    C2 PSR
    0
    C2 LTSR
    0
    Mean PS
    28.8
    Mean PSR
    10.0
    Mean LTSR
    0.0
  • Claude Opus 5.5
    A1 PS
    0
    A1 PSR
    0
    A1 LTSR
    0
    A2 PS
    82
    A2 PSR
    70
    A2 LTSR
    0
    B1 PS
    40
    B1 PSR
    0
    B1 LTSR
    0
    B2 PS
    20
    B2 PSR
    0
    B2 LTSR
    0
    C1 PS
    0
    C1 PSR
    0
    C1 LTSR
    0
    C2 PS
    0
    C2 PSR
    0
    C2 LTSR
    0
    Mean PS
    23.7
    Mean PSR
    11.7
    Mean LTSR
    0.0
  • Qwen3.8-27B
    A1 PS
    0
    A1 PSR
    0
    A1 LTSR
    0
    A2 PS
    12
    A2 PSR
    0
    A2 LTSR
    0
    B1 PS
    30
    B1 PSR
    0
    B1 LTSR
    0
    B2 PS
    10
    B2 PSR
    0
    B2 LTSR
    0
    C1 PS
    15
    C1 PSR
    0
    C1 LTSR
    0
    C2 PS
    0
    C2 PSR
    0
    C2 LTSR
    0
    Mean PS
    11.2
    Mean PSR
    0.0
    Mean LTSR
    0.0
  • DeepSeek V4.1 Flash
    A1 PS
    0
    A1 PSR
    0
    A1 LTSR
    0
    A2 PS
    24
    A2 PSR
    0
    A2 LTSR
    0
    B1 PS
    5
    B1 PSR
    0
    B1 LTSR
    0
    B2 PS
    0
    B2 PSR
    0
    B2 LTSR
    0
    C1 PS
    0
    C1 PSR
    0
    C1 LTSR
    0
    C2 PS
    0
    C2 PSR
    0
    C2 LTSR
    0
    Mean PS
    4.8
    Mean PSR
    0.0
    Mean LTSR
    0.0
Figure 12: Real-robot scores against simulated scores for the six VLMs run in both settings. Horizontal axis: simulated Overall, from Tab. 26 for Gemini 4 Argon, GPT-6 Astra, GPT-6.1 Sol, and Claude Opus 5.5, and from Tab. 5 for Qwen3.8-27B and DeepSeek V4.1 Flash. Vertical axis: mean over the real-robot tasks (Tab. 30). Dashed line: least-squares fit through the six points. \rho: Spearman rank correlation, with tied models sharing their mean rank.
Results.

No model completes a Throughput task (best PS 21.5 on C1), while Gemini 4 Argon and GPT-6 Astra solve A2 in every episode (Tab. 30). On A2 and B1 every completed episode exceeds its time requirement, so LTSR is nonzero only on A1 and B2, and only for these two models. Mean PS is about 54 for the leading two, 28.8 and 23.7 for GPT-6.1 Sol and Claude Opus 5.5, and 11.2 and 4.8 for the open-weight models.

Comparison with the simulated ranking.

Fig. 12 compares the real-robot means with the simulated Overall values: Tab. 26 for Gemini 4 Argon, GPT-6 Astra, GPT-6.1 Sol, and Claude Opus 5.5, and Tab. 5 for Qwen3.8-27B and DeepSeek V4.1 Flash. The rankings agree, with Spearman \rho=1.00 for PS, 0.93 for PSR, and 0.85 for LTSR. In LTSR, Gemini 4 Argon leads GPT-6 Astra in both settings, while the other four models score at most 2.3% in simulation and zero on the arm. Absolute rates and interface versions differ across episodes, so this pilot comparison is descriptive and does not establish a mapping of success rates.