Fast Muscle-Driven Whole-Body Motion Tracking with a Differentiable World Model
An arXiv preprint adapts SuperMimic to track motion capture with two simulated whole-body muscle models. On one RTX 5090, MS-Human-700 reached the baseline score in 6.3 minutes versus 3.9 hours, a 37-fold speedup that makes repeated controller tuning more practical.
Can a differentiable world model train whole-body muscle controllers in minutes while preserving accuracy on unseen motions, and can it improve their actions at test time?
A muscle-driven body follows motion capture by coordinating hundreds of bounded excitations through changing contacts. Muscle activation lags the command, and multiple muscles can act on the same joint. Direct-torque recipes miss these dynamics, and some training settings that work on rigid humanoids destabilize muscle control.
MuscleMimic and MS-Emulator train with model-free PPO. MuscleMimic used 3.2 billion steps and about three days on an H100, while MS-Emulator reported 7 hours on an RTX 5090 for a single running trajectory. InstantTrack and BlinkMimic sped up SuperMimic on the rigid Unitree G1, but several settings needed changes for muscle actuation.
A learned model predicts velocity changes and foot contacts while stepping muscle activation with MuJoCo's own update rule. The controller learns by backpropagating tracking rewards through predicted trajectories. The fast recipe drops muscle geometry from observations, overlaps simulation and updates on CUDA streams, uses mean-preserving Beta exploration and controls at 50 Hz. Training uses 972 KIT clips from AMASS. The simulated MS-Human-700 drives 694 muscles with its hands locked, and MyoFullBody uses 354.
In MuJoCo-Warp, 108 held-out KIT clips were evaluated once per policy, with results averaged over three seeds for the fast recipe. On one RTX 5090 with warm caches, normalized return reached 0.83 in 6.3 minutes versus 3.9 hours on MS-Human-700 (37-fold faster) and in 10.5 minutes versus 6.0 hours on MyoFullBody (34-fold faster, with the same settings). Both baselines used SuperMimic's published hyperparameters. On MS-Human-700, 20 minutes at 50 Hz yielded a pelvis-relative mean per-joint position error (MPJPE) of 18.2 mm and independent-joint angle MAE of 3.37°, versus 22.4 mm and 5.14° after 10.1 hours for the baseline. Five test-time gradient steps cut MPJPE to 13.5 mm (26%) and global MPJPE from 123 to 58 mm (53%), with zero failures. With refinement, the 0.83 threshold took 5.1 minutes of training. On MyoFullBody, the 20-minute policy averaged 1.0 failed clips versus 3.7 for the released MuscleMimic tracker on the same split. MPJPE was 28.0 versus 25.0 mm, and refinement brought it to 23.6 mm with zero failures.
All tests ran in simulation. A fresh setup needs about 9 minutes before the first policy update. Refinement costs about four times as much per control step and runs below real time. The main KIT clips last about 5 s. After one hour of training, drift ended all seven held-out LAFAN1 clips on MS-Human-700 at 7 to 25 s. Adding the reference root position and refining actions raised average completions to 5.5 of seven. Missing arm and hand collision geometry rules out hand-supported motions on MS-Human-700. Activation correlation with walking EMG was about 0.1 across eleven leg muscles.
Animation software vendors and biomechanics simulation teams could use the approach within 1 to 3 years to shorten controller iteration. Longer sequences need drift control, interactive products need real-time refinement, and assistive-device teams would need physiological validation before using the simulated activations in design decisions.
The full text is not republished here because the paper's license does not allow it. Read the original on arXiv.